Laserfiche WebLink
§FbUD PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - (Pae 1 of 2) <br /> 490-1. <br /> TYPE OF ACTION ❑ 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION <br /> PLAN TYPE ❑ 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> L FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as Facility Name or DBA) WEST VALLEY AUTO SPA INC. 3 <br /> BUSINESS SITE ADDRESS 2615 West GRANT LINE ROAD 103. 1 CITY TRACY 104. <br /> IL EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel.123 CCR§2632,2634,2638,26411 <br /> 490-3a. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3b. <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLANIMAP PREVIOUSLY SUBMITTED [23 CCR§2632,2634) 490-4. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) t ahiak Irr <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERST mAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 4906. <br /> PANEL MANUFACTURER: VEEDER ROOT 490-7. MODEL#: VR TLS 35OR 490-8. <br /> LEAK SENSOR MANUFACTURER: VEEDER ROOT 490-9. MODEL#(S): VR-303 490-10. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 490-11. <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14 MODEL#(S): 490-M <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHT'LY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 49-17. <br /> 90 <br /> PROGRAMMED TESTS: ❑ a.0.1&p.h. [Ib.0.2 g p.h. ❑ c.OTHER(Specify): 490 19.18 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.11 490-20. <br /> 21. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 49 490 <br /> -22.22. <br /> _ <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 490-23. <br /> TEST FREQUENCY: [I a.ANNUALLY [Ib.BIENNIALLY [I c.OTHER(Specify): 2524. <br /> ❑ 99.OTHER(Specify): ----------- ---- - ----- 490-26 <br /> -90-27. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHODS) <br /> that apply) <br /> ll <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [§�] SECONDARY CONTAINMENT IS: a.DRY [Ib.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-29. <br /> PANEL MANUFACTURER:VEEDER ROOT 490-30 MODEL#: VR TLS 35OR 490-31. <br /> LEAK SENSOR MANUFACTURER: VEEDER ROOT 49x32. MODEL#(S): VR-208 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ED &YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-31. <br /> ❑ 2. MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h LEAK TESTS AND RESTRICTS OR SHUTS OFF 491)-36- <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23CCR§26361 <br /> MLLD MANUFACTURER(S): 490-37. MODEL#(S): 490-38. <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g p.h.LEAK TESTS.[23 CCP§26361 490-39. <br /> ELLD MANUFACTURER(S):VEEDER ROOT 49040. MODEL#(S): PLLD(8484) 49041. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a_MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49-42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49043. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49-44. <br /> ❑ 4.PIPE INTEGRITY TESTING. 4%45. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS [Iyo <br /> c.OTHER(Specify) 449o.46. <br /> ❑ 5. VISUAL PIPE MONITORING. 490-48. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 49049. <br /> .Allowed for mondonng of unburned®agency genaator fuel piping only per HSC§25281.5(6x3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(a)(3)1 490-50. <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> ago <br /> 0 99.OTHER(Specify) 490-53. <br />