My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2023 4:42:56 PM
Creation date
2/27/2020 2:19:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (two pages per tank) <br /> Page-of_ <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same asFACILITY NAME orDBA-Doing Business As) 3 FACILITY ID: <br /> Ll <br /> 1 = Cts t1 111 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> L TANK DESCRIPTION (A scaled plot plan With the location of the UST system including buildings and landmarks shall be submitted t the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK Yes ❑ No 434 <br /> If"Yes",complete one page for each compartment- <br /> DATE <br /> mpartment- <br /> DATnnE,,NS,,TAL D(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> A�(/U <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> H.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> 1. MOTOR VEHICLE FUEL Q REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL Cl 99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Includes Used Oil) -// / n [[�// ( / I ( \ S✓ao -(,e(- <br /> 0 <br /> `,C /-❑95.UNKNOWN J <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ElGLE WALL 3. SINGLE WALL WITH 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) iEXTERIOR MEMBRANE LINER 095. UNKNOWN <br /> 2. DOUBLE WALL [_14. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 1. BARE STEEL 3. FIBERGLASS/PLASTIC 5. CONCRETE 0 95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> INFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank Ll 1. BARE STEEL M 3. FIBERGLASS/PLASTIC U 5. CONCRETE U 95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL [199.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> Cl 5. CONCRETE <br /> TANK INTERIOR LINING 0 1.RUBBER LINED 0 3.EPDXY LINING LASS LINING 095.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING r6UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check we item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 71,xLARM <br /> ILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) SPILL CONTAINMENT ❑3 FILL TUBE SHUT OFF VALVE <br /> (� ROP TUBE O X2BALL FLOAT ❑4 EXEMPT <br /> 3 STRIKER PLATE <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Chet ne item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑ VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION Cl 8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DA Y) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) 10 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.