My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
INSTALL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2020 10:41:34 PM
Creation date
2/27/2020 3:48:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2004
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY DATE0 <br /> PR# <br /> VIRONMENTAL HEALTH DEPAR'. ",IT PAGE I !- <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK (UST)-PROGRAM INSPECTION REPORT <br /> � t Facility Name_ C�R oLFacilityAddress <br /> �� �1► \t` ��;� <br /> Facilty Contact'I W _ Title Iry 'i GL' �Phone # �1�.55 �( . <br /> UST# Product UST#_2 Productl. e iA UST# ? ProducUST# Product <br /> Overfill Prevention: ClAudible/Visual ❑ Mechanical Monitoring Panel: 1 LS ' <br /> Piping System: ❑ Gravity ❑`VSressure ❑ Suction Violations: ❑ M1-RDet E M2-Rprev ❑ M3-Both <br /> Automatic Pump Shut Down Satisfies CCR 2636 (f)(5): 9'Yes ❑ No Designated Operator: <br /> INSPECTION TYPE: [9Routine ❑Monitoring Certification ❑Complaint nstall ❑Removal ❑Repair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: �L - �� '.h PHONE:���. . t{l� CA c) 1 <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 23 CCR 2643 (d) Daily monitoring of suction <br /> 2 CCR 2637 Secondary cont. testing piping (pre-1/1/84) <br /> 3 CCR 2711(b) & (c) Current State Forms A& B 24 CCR 2636 (a) Conventional suction piping <br /> 4 HSC 25292.2 Certification of financial shall have continuous <br /> responsibility& CFO letter monitoring &20 containment <br /> 5 CCR 2632 (c)(2) UST monitoring is present (M1) 25 CCR 2643 (e) Biennial tightness test of gravit, <br /> 6 CCR 2630 (d) UST system monitoring piping (pre-1/1/84) <br /> equipment is properly located.to 26 CCR 2643 (d) Triennial line test for <br /> detect a leak (M1) conventional suction (pre- <br /> 7 CCR 2637(b) UST system monitoring 1/1/84) (M1) <br /> equipment is operational (M1) 27 CCR 2661 Permit to repair UST system <br /> 8 CCR 2636 (f)(1) Continuous monitoring system 28 HSC 25286 (a) Permit to alter monitoring <br /> for underground piping & UDC system <br /> is present(M1) 29 HSC 25298 (a) Illegal abandonment of UST <br /> 9 CCR 2636 (c)(1) All releases in secondary piping system <br /> flow to a collection sump 30 HSC 25298 (b) Permit to temporarily close LIS- <br /> 10 HSC 25291 (f) Line leak detector(s) (M1) system <br /> 11 HSC 25291(a)(2) Secondary containment for 31 HSC 25298 (c) Permit to close UST system <br /> UST is tight 32 HSC 25292.1 UST system is operated to <br /> 12 CCR 2635 (b)(1) Spill container(M2) prevent unauthorized release <br /> 13 HSC 25284.2 Annual spill container testing 33 CCR 2650 Recording/reporting <br /> 14 CCR 2635 (b)(2) Overfill prevention system (M2) unauthorized release (M1) <br /> 15 CCR 2631 (a) Primary containment is product--_ 34 HSC 25291 (e) Water in 20 cont analyzed and <br /> tight properly disposed of <br /> 16 CCR 2632 (d) Monitoring & response plan 35 CCR 2640 (e) Single wall component within <br /> 1' CCR 2712 (i) Monitoring & response plan is 1 000' of Public Well, no ELD <br /> on site 36 CCR 2635(a)(2)(A)Cathodic protection testing & <br /> 18d CCR 2712 (b) Maintenance & monitoring 60 day inspection log (M2) <br /> records (M1) 37 H&SC 25299(a)(9)Disabling leak detect. Devices <br /> 19 CCR 2636 (f)(4) Annual line tightness test 38 CCR 2715(a) Statement from UST owner <br /> 20 CCR 2630 (d) Annual line leak detector test 39 CCR 2715(c) Monthly inspection by D.O, <br /> (M1) 40 CCR 2715 (f) D.O. trained employees <br /> 21 CCR 2630 (d) Annual monitoring certification 41 Violation(s) not listed above <br /> 22 CCR 2661 (f) Repair for tank/piping has had <br /> tightness test M2 <br /> EHD INSPECTOR: �lZ 't Zc%' _ C�C��� ' ' PHONE: �( �1. ��. _ <br /> RECEIVED BY: _ _ TITLE: <br /> Septic System: ❑Serves z 20 persons/day ❑Receives other than sanitary waste <br /> Other Disposal Units Identified: ❑Dry wells/French Drains <br /> I:\UnitS\Unit•III\UST\UST inspectiona.19.04.DOC <br />
The URL can be used to link to this page
Your browser does not support the video tag.