My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
INSTALL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2020 10:41:34 PM
Creation date
2/27/2020 3:48:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2004
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
386
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping system Secondary employs full-performance pipe— Many contained fuel handling systems <br /> characteristics employ materials in the secondary that fall far short of the primary piping in regards to <br /> chemical resistance and mechanical strength.By contrast,Dualoy 3000/L systems <br /> employ the same type of high-performance fiberglass-reinforced pipe in the secondary <br /> as in the primary.Thus,Dualoy 3000/L containment systems easily withstand both high <br /> external loads from backfill and traffic as well as internal pressures as high as 100 psig. <br /> Compact containment fittings—Dualoy 3000/1-containment fittings are more <br /> compact than competitive clam-shell type closure pieces.As a result,crossovers in a <br /> Dualoy 3000/L system occupy less space,so less excavation is required than with <br /> competing rigid-wall containment systems. <br /> Precision pipe exterior eliminates scarfing—Dualoy pipe is manufactured in a <br /> - proprietary continuous winding process that provides an extremely precise,consistent <br /> outside diameter.No scarfing of the pipe end is required to achieve a proper fit of the <br /> secondary pipe inside closure pieces.Light sanding of the pipe end to remove the <br /> Only end prep required surface gloss and obtain a suitable bonding surface is the only end prep required. <br /> is the removalface t <br /> sanding of surface _- Easy accessibility to primary fittings— Dualoy systems provide convenient access to <br /> gloss. primary fittings during bonding,testing and inspection by using lengths of containment <br /> pipe of different diameters and appropriate reducing couplings.In most layouts the <br /> The end section of a run of <br /> containment pipe is placed inside I I I I <br /> the center section,providing easy <br /> access to the primaryjoint atone <br /> end of the run. — — — —__— — — — — _ <br /> primary can be contained by three pieces of secondary pipe as shown above.The 3-inch <br /> lengths at the ends of the run are one size largerthan the primary line;the middle piece is <br /> 31/2-inch containment pipe.The 3-inch containment sections slip readily inside the <br /> 31/2-inch section.By manipulating the sections,ready access to the primary fittings can <br /> be achieved during installation and testing. <br /> Complete retestability— Dualoy 3000/1-containment employs rigid-wall pipe and <br /> fittings that maintain their shape during the entire service life of the station.When <br /> installed with isolating penetration fittings(see page 4),Dualoy 3000/1-containment <br /> piping can be repeatedly retested whenever desired. <br /> Rapid containment fitting assembly with the Ameron Rivetool—Owing to the <br /> extremely precise outside diameter control of Dualoy 3000/1-containment pipe and the <br /> ample thickness of Ameron containment fittings,Dualoy 3000/1-containment systems <br /> can be assembled with rivets rather than cumbersome wing-nuts or conventional bolts. <br /> The easy-to-use pneumatic Ameron Rivetool provides identical tension on every rivet. <br /> Riveted closure is four to five times faster than closure with bolts. <br /> Convenient repair capability—Contained piping systems are occasionally damaged <br /> after installation.Damage is generally caused by paving or excavation operations.Dualoy <br /> 3000/1-contained piping systems are designed so that only the damaged stretch need be <br /> replaced instead of the entire line.The 2-inch Dualoy repair coupling is sized so that it can <br /> be contained within 4-inch Dualoy 3000/L containment pipe. <br /> 4 x 3 inch reducing <br /> Two-inch primary pipe contained within <br /> couplings <br /> 3-inch or3'f2.-inch containment pipe can 2-inch repair coupling\ <br /> be repaired with a UL-listed 2-inch repairo 0 0 <br /> coupling.The containment is restored by o <br /> replacement of a section of the existing ° o_ o ° <br /> containment pipe with a 4-inch <br /> containment nipple.The 4-inch <br /> replacement nipple is then joined to the o 0 0 0 <br /> existing containment pipe with Dualoy o <br /> o ° <br /> reducing couplings. ° <br /> Align wing-nuts parallel to pipe to permit <br /> i <br /> 4-inch pipe 4-inch pipe to slip over repair coupling <br />