My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:16:18 AM
Creation date
2/28/2020 11:57:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,WWR.CB, ?anuary 2002 Page 2 of 2 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: r UDC Manufacturer r Industry Standard (• Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure r Vacuum r. Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used:[VKtj Equipment Resolution: Q�Q01701_in__; <br /> UDC#9/10 UDC#11/12 UDC # UDC # <br /> UDC Manufacturer: unknown unknown <br /> UDC Material: Fiberglass Fiberglass <br /> UDC Depth: 30.00 30.00 <br /> Height from UDC Bottom to Top of 15.00 15.00 <br /> Highest Piping Penetration: <br /> Height from UDC Bottom to Lowest 3.00 <br /> Electrical Penetration: 32.00 <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested t 17 17 <br /> Does turbine shut down when UDC <br /> sensor detects liquid(both product and f Yes r No 0 NA r Yes r Nor* NA r Yes r No r NA r Yes r Nor NA <br /> watei <br /> Turbine shutdown response time Sec SEC SEC sec <br /> Is system programmed for fall-sate <br /> shutdown?• Yesr Nor- NA C Yes r Nor: NA r Yes (- Noll r Yes r No r NA <br /> Was fall-safe verified to be operational' r Yes r Nor NA r Yes r Nor* NA r Yes (- Nor NA r Yes r Nor NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting test 5 min 5 min min min <br /> Test Start Time: 14:18:00 14:23:00 <br /> Initial Reading(RI): 0.00000 in. H2O 0.00000 In. H2O <br /> Test End Time: 14:33:00 14:38:00 <br /> Final Reading(RF): 0.00060 in. H2O -0.00020 in. H2O <br /> Test Duration: 15 min 15 min <br /> Change In Reading(RF-RI): 0.00060 In. H2O -0.00020 in. H2O <br /> Pass/Fail Threshold or Criteria: +/- 0.00200 +/- 0.00200 +/- <br /> Test Result: Pass Pass <br /> was sensor removed for testing? r:. Yes r No r NA r Yes r Nor NA r Yes r Nor NA r Yes (- Nor NA <br /> Was sensor properly replaced and <br /> verified functional after testing? re Yes r No r NA 0Yes r Nor NA r Yes r No r NA r Yes r No r NA <br /> Comments ?(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> F ---— <br /> .................... <br /> ------ — — —._ _ <br /> I If the entire depth of the UDC is not tested,specify how much was tested.If the answer to any of the questions indicated with an asterisk(')is?NO? or?NA?, the <br /> entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.