My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:16:18 AM
Creation date
2/28/2020 11:57:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 1 of 1 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: f Sump Manufacturer f Industry Standard fo Professional Engineer <br /> f Other(Specify) <br /> Test Method Used By: r Pressure f Vacuum Co Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used: VPLT Equipment Resolution: 0.00001 in. <br /> Sump# Sump# Sump# Sump# <br /> Sump Diameter: in. In. in. in. <br /> Sump Depth: In. In. In. In. <br /> Sump Material: <br /> Height from Tank Top to Top of Highest <br /> Piping Penetration: <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: <br /> Condition of sump prior to testing: <br /> Portion of Sump Testedl <br /> Does turbine shut down when sump <br /> sensor detects liquid(both product and r Yes r No r NA r Yes r No r NA r Yes r Nor NA r Yes r Nor NA <br /> water)?* <br /> Turbine shutdown response time SEC Sec Sec sec <br /> Is system programmed for fall-safe r Yes r Nor NA r Yes r No r NA r Yes r Nor NA r Yes r No r NA <br /> shutdown?- <br /> Was fail-safe verified to be operational? f Yes r Nor NA r Yes r Nor NA r Yes r Nor NA r Yes r No r NA <br /> Walt time between applying <br /> pressure/vacuum/water and starting m i n min m i n m 1 n <br /> test <br /> Test Start Tlme: <br /> Initial Reading(RI): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duratlon: <br /> Change In Reading(RF-RI) <br /> Pass/Fall Threshold or Criteria: +/- +/- <br /> Test Result: <br /> was sensor removed for testing? r Yes r No r NA r Yes r No r NA r Yes r Nor NA r Yes r Nor NA <br /> Was sensor properiy replaced and (" Yes r Nor NA r Yes r No r NA r Yes r Nor NA r Yes r Nor NA <br /> verified functional after testing? <br /> comments 7(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> vent sump 24x30, 34",fiberglass, 10",10", good, 12" n/a, n/a, n/a, n/a, 5 min, 12:31, 0, 13:01, -0.0009, 30mins, -0.0009, .f ; <br /> 0.0020, pass, yes, yes, (unable to test 87, 91, and diesel piping sumps, due to the fact of the sump boots are cracked anu <br /> broken. <br /> 1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is <br /> ?NO? or?NA?, the entire sump must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.