Laserfiche WebLink
ANOL <br /> LE PETROLEUM SERVICES INC. Page of <br /> RELIAB _ <br /> L 4:PREMIUM ANN. Q 2-:PREMIUM <br /> DUAL POINT HYDROSTATIC OUTPUT RELAY SETUP - - _ IN-TANK ALARMS <br /> CATEGORY : ANNULAR SPACE - - - - - - <br /> T 1 :HIGH WATER ALARM <br /> R 4:OVERFILL ALARM T I :LOW PRODUCT ALARM <br /> TYPE: <br /> L 5:PREMIUM STP SUMP STANDARD LIQUID SENSOR ALMS <br /> TRI-STATE (SINGLE FLOAT) NORMALLY OPEN L 5:FUEL ALARM <br /> CATEGORY : STP SUMP L10:FUEL ALARM <br /> TANK tt: NONE L11 :FUEL ALARM <br /> L12:FUEL ALARM <br /> L 6:PREMIUM FILL SUMP L13:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) IN-TANK ALARMS L14:FUEL ALARM <br /> CATEGORY : PIPING SUMP ALL:OVERFILL ALARM L15:FUEL ALARM <br /> ALL:HIGH PRODUCT ALARM L 5:SENSOR OUT ALARM <br /> ALL:MAX PRODUCT ALARM L10:SENSOR OUT ALARM <br /> L 7:DIESEL STP SUMP LII :SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L12:SENSOR OUT ALARM <br /> CATEGORY : STP SUMP L13:SENSOR OUT ALARM <br /> L14:SENSOR OUT ALARM <br /> L15:SENSOR OUT ALARM <br /> L 8:DIESEL FILL SUMP L 5:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) L10:SHORT ALARM <br /> CATEGORY : PIPING SUMP L11 :SHORT ALARM <br /> L12:SHORT ALARM <br /> L13:SHORT ALARM <br /> L 9:VENT SUMPL14:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) PLLD LINE DISABLE SETUP L15:SHORT ALARM <br /> CATEGORY OTHER SENSORS - - - - - - - - - - - <br /> PRESSURE LINE LEAK <br /> Q 1 :REGULAR ALL:PLLD OPEN ALARM <br /> Q 2:LN EQUIP FAULT ALM <br /> L10:DISP. 9-10 IN-TANK ALARMS <br /> TRI-STATE (SINGLE FLOAT) T 3:HIGH WATER ALARM ISD SITE ALARMS <br /> CATEGORY DISPENSER PAN T 3:LOW PRODUCT ALARM ISD GROSS PRES FAIL <br /> LISD DEGRD PRES FAIL <br /> LIQUID SENSOR ALMS <br /> ISA VAPOR LEAK FAIL <br /> L 2:FUEL ALARM ISA VP PRES FAIL <br /> L11 :DISP. 11-12 L10:FUEL ALARM ISD VP STATUS FAIL <br /> TRI-STATE (SINGLE FLOAT) L11 :FUEL ALARM ISD SETUP FAIL <br /> CATEGORY : DISPENSER PAN L12:FUEL ALARM <br /> L13:FUEL ALARM <br /> L14:FUEL ALARM ISD HOSE ALARMS <br /> L15:FUEL ALARM ALL:GROSS COLLECT FAIL <br /> L12:DISP. 7-8 L 2:SENSOR OUT ALARM ALL:DEGRD COLLECT FAIL <br /> TRI-STATE (SINGLE FLOAT) L10:SENSOR OUT ALARM ALL:FLOW COLLECT FAIL <br /> CATEGORY : DISPENSER PAN L11 :SENSOR OUT ALARM <br /> L12:SENSOR OUT ALARM Q 3:DIESEL <br /> L13:SENSOR OUT ALARM <br /> L14:SENSOR OUT ALARM IN-TANK ALARMS <br /> L13:DISP. 5-6 L15:SENSOR OUT ALARM T 2:HIGH WATER ALARM <br /> TRI-STATE (SINGLE FLOAT) L 2:SHORT ALARM T 2:LOW PRODUCT ALARM <br /> CATEGORY : DISPENSER PAN 1_10:SHORT ALARM <br /> L11 :SHORT ALARM LIQUID SENSOR ALMS <br /> L12:SHORT ALARM L 7:FUEL ALARM <br /> L13:SHORT ALARM L10:FUEL ALARM <br /> L14:DISP. 1-2 L14:SHORT ALARM L11 :FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L15:SHORT.ALARM L12:FUEL ALARM <br /> CATEGORY DISPENSER PAN L13:FUEL ALARM <br /> PRESSURE LINE LEAK L14:FUEL ALARM <br /> ALL:PLLD OPEN ALARM L15:FUEL ALARM <br /> Q 1 :LN EQUIP FAULT ALM L 7:SENSOR OUT ALARM <br /> L15:DISP. 3-4 L10:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) ISD SITE ALARMS L11 :SENSOR OUT ALARM <br /> CATEGORY DISPENSER PAN ISD GROSS PRES FAIL L12:SENSOR OUT ALARM <br /> ISD DEGRD PRES FAIL L13:SENSOR OUT ALARM <br /> ISD VAPOR LEAK FAIL L14:SENSOR OUT ALARM <br /> ISD VP PRES FAIL L15:SENSOR OUT ALARM <br /> ISD VP STATUS FAIL L 7:SHORT ALARM <br /> ISD SETUP FAIL L10:SHORT ALARM <br /> L11 :SHORT ALARM <br /> ISD HOSE ALARMS L12:SHORT ALARM <br /> L13:SHORT ALARM <br /> ALL:GROSS COLLECT FAIL L14:SHORT ALARM <br /> ALL:DEGRD COLLECT FAIL L15:SHORT ALARM <br /> ALL:FLOW COLLECT FAIL <br />