My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:13:35 AM
Creation date
2/28/2020 1:04:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE PIPING/DISPENSER REMOVAL/REPLACEMENT <br /> The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br /> representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. Samples <br /> cannot be combined into a composite sample for analysis in the field or the lab. Each sample must have a set of <br /> corresponding analytical results. If contamination is documented during closure. an Unauthorized Release Notification must be <br /> completed and submitted within five(5)working days pursuant to California Health& Safety Code, Section 25295. <br /> DISPENSER PIPING AND STOCKPILE SAMPLES <br /> DISPENSER SAMPLES 1 Sample beneath each dispenser <br /> PIPING SOIL SAMPLES 1 Sample every 20 lineal feet N <br /> =s� <br /> DISPENSER& PIPING STOCKPILE SAMPLES 2 Samples every 50 cubic yards` <br /> TABLE #2 RECOMMENDED MINIMUM VERIFICATION ANALYSESE:NVIRONMENTAL <br /> FOR UNDERGROUND STORAGE TANK INVESTIGATIONS"'r,_, n�a"RTtinENT <br /> TANK TANK Gasoline Diesel BTEX V0Cs0) Semi- Oil& PCB Total Title 22 <br /> # CONTENTS VOCs(2) Grease Lead Metals(3) <br /> 8015M 8021B 8260B 8082 7421 <br /> 8260B 8015M 82608 8270C 1664A <br /> Unknown Fuel <br /> (C4-C36) X X X X <br /> Gasoline <br /> (C4-C20) X X X <br /> Diesel <br /> (C10—C36) X X X <br /> Jet Fuel/Kerosene <br /> (C9-C20) X X <br /> Heating Oil <br /> (C10-C32) X X <br /> Stoddard Solvent <br /> (non-chlorinated) X X <br /> (C8-C20) <br /> Chlorinated <br /> Solvents X X <br /> Waste Oil or X X X <br /> Unknown Contents X X X X <br /> Notes: <br /> 1. EPA Method 8260B analyses must include all analytes listed in the method plus fuel oxygenates methyl- <br /> tertiary-butyl ether(MTBE), diisopropyl ether (DIPE). ethyl-tertiary-butyl ether(EtBE), tertiary-amyl-methyl <br /> ether (TAME), tertiary-butanol (TBA), methanol and ethanol and fuel additives 1,2-dichloroethane (1,2-DCA) <br /> and ethylene dibromide (EDB or 1,2-dibromoethane). <br /> 2. If pentachlorophenol (PCP) is identified, analyze the soil and/or water sample for dioxins and furans by EPA <br /> Method 8290 and pesticides by EPA Method 8081A. <br /> 3. Title 22 Metals: Method 6010B may be used for all but the following metals, for which individual AA methods <br /> are required: Antimony &Arsenic by 7062, Cadmium by 7131A, Lead by 7421, Mercury by 7471A, Nickel by <br /> 7521, Selenium by 7742, and Thallium by 7841. <br /> 4. Non-proprietary, performance based analytical methods may be used with approval of Regional Board staff. <br /> EH230038(revised 7-26-2016) 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.