My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:13:35 AM
Creation date
2/28/2020 1:04:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.or-/q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WEST VALLEY AUTO SERVICE LLC 2615 W GRANT LINE RD, TRACY June 28, 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status -V -R =COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status =V R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag -V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST =V -R =COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms -V =R =COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored -V -R COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V -R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements V ❑R ❑COS <br /> 330 j CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system V ❑R ❑COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V -R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> Fuel was found in 87 product STP sump. Technician confirmed the presence of fuel in the sump and indicated <br /> amount removed to be around a quart of fuel. This is indicative of a leak in the primary piping. All primary <br /> containment for the UST system must be tight. Immediately have a properly licensed, trained, and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD. <br /> This is a minor violation. <br /> 319 CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br /> The diesel, 87 and 91 product UST is not equipped with a spill container that holds five gallons. All USTs shall be <br /> equipped with a spill container that has a minimum capacity of five gallons and a drain valve that allows drainage of <br /> the collected spill into the primary container or provide a means to keep the container empty. Once the spill <br /> containers fail a tightness test or are replaced the must be replaced with a 5 gallon capacity spill container. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0014623 PR0521537 SC333 06/28/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.