My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:13:35 AM
Creation date
2/28/2020 1:04:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County APR 15 2016 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 tRacw: <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.si4ov.orolehd <br /> ; R ., Po �ndSW " arlv:rOT <br /> M <br /> 1cr 3. <br /> 10 <br /> Facility Name: Facility Phone: Date: <br /> WEST VALLEY AUTO SERVICE LLC 209 836-3464 March 14 2016 <br /> Facility Address: CERS ID: <br /> 2615 W GRANT LINE RD TRACY CA 95304 10184725 <br /> Inspection Contact: Title: Phone: <br /> James Riddle Mana er 209 836-3464 <br /> inspection Type: Program: <br /> ROUTINE INSPECTION -O eratin Permit 2371 - UST FACILITY- 1702 COMPLIANT <br /> Consent For: Consent Given By: <br /> 21 Inspection 9 Photos O Sam les James Riddle Mana er, <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Tony Fontana 05/2912016 Rick Branchini 07/17/2016 <br /> Service Technician Manufacturer's Training <br /> Veeder Root, 08/10/17; VMI, 06/13/17 <br /> C R-=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> 101 HSC 25284 No permit to operate V R COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system r.�V R _COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted =V ❑R COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current V r.R n COS <br /> 105 HSC 25286(c) Current BOE number not submitted ■V u R ■COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD V n R n COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V :,R ■COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing 0 V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment : V n R n COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days V u R L I COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually T,V u R n COS <br /> 112 HSC 25284.2 Failed to test spill containers annually V n R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days r-V n R n COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down -V n R c COS <br /> 115 CCR 2715(,) Failed to inform the EHD of a change of designated operator within 30 days w V ❑R ■COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification n V i;R r COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1 000'of a public well _ o V ❑R c COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test o V ❑R c COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days c V r R n COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after n V r,R n COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V n R n COS <br /> 122 HSC 25299 Documents were falsified or misrepresented 7,V n R n COS <br /> 123 CCR 2661 Permit to repair UST system not obtained n V n R --COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification n V n R r,COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report a V R , COS <br /> 126 HSC 25404(e)(4) Failed to report program data electronically o V c R z COS <br /> Page 1 of 6 <br />