My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:13:35 AM
Creation date
2/28/2020 1:04:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M1rlfrun-RYAN INc. Job# 20-630774.1 <br /> SWRC&,January 2002 Page 2 of 3 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: Tank Manufacturer industry Standard Professional Engineer <br /> Other(specify) <br /> Test Method Used: Pressure Vacuum Hydrostatic <br /> Other(specify) <br /> Test Equipment Used: Incon Equipment Resolution: 0.0001 <br /> SUMP# Fent SUMP4 SUMP# Sum # <br /> Sump Diameter: 24" <br /> Sump Depth: 31" <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 10" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest <br /> 14" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Good <br /> Portion of Sump Tested(l) Above Penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both Yes :'No; NA Yes No NA Yes No NA Yes No NA <br /> product and water)?* <br /> Turbine shutdown response time N/A <br /> Is system programmed for fail-safe <br /> Yes No: NA Yes No NA Yes No NA Yes No NA <br /> shutdown?* is; <br /> Was fail-safe verified to be <br /> Yes No; NA Yes No NA Yes No NA Yes No NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting lOntin <br /> test: <br /> Test Start Time: 11:20 <br /> Initial Reading(Ri): 4.8340 <br /> Test End Time: 11:35 <br /> Final Reading(Ro 4.8345 <br /> Test duration: 15min <br /> Change in Reading(Rf-Ri): 0.0005 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Results: X Pass Fail Pass Fail Pass Fail Pass Fail <br /> Was sensor removed for testing? f c 3 No NA Yes No NA Yes No NA Yes No NA <br /> Was sensor properly replaced and <br /> verified functional after testing? €sry No NA Yes No NA Yes No NA Yes No NA <br /> Comments-(include information on repairs made prior to testing,and recommend follow-up for failed tests) <br /> (1)If the entire depth of the sump is not tested,specify how much was tested.If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested.(See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.