My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2020 9:13:35 AM
Creation date
2/28/2020 1:04:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
476
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County AECEIVELEI)/1 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.s'gov.org/ehd MAY 0 4 2015 <br /> (] ora ems..Tank ,�ro <br /> Facility Name: Facility Address: at "IIT"IFNIT <br /> WEST VALLEY AUTO SPA* 2615 W GRANT LINE RD TRACY March 25 2015 <br /> iw SUMMARY OF VIOL. <br /> "> SSS II,or MINOR <br /> Item # Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to attach November 2014 and January 2015 alarm history to the designated operator <br /> monthly inspection report. The designated operator failed to attach the Q1:Regular, Q2:Premium and Q3:Diesel alarm <br /> history for all twelve months of the designated operator monthly inspection report and failed document the dates for <br /> L9: Vent Sump and L5: Dispenser 3/4 that occurred on December 12, 2014 and February 10, 2015 in the designated <br /> operator monthly report. During the monthly inspection, the designated operator shall review the alarm history for the <br /> previous month, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> ,i <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training log did not have the hiring dates of all employees. A list of facility <br /> employees who have been trained by the designated operator(s), shall be maintained on-site and shall include the <br /> dates of training for all facility employees, and hiring dates for all facility employees hired on or after July 1, 2005. <br /> This is a minor violation. <br /> 315 HSC 25290.2(c)(1) Primary containment not tight (Jul 2003-Jun2004). <br /> Observed 1/2 cup of fuel in the 87 STP sump, indicating a leak in the primary piping. Service technician removed the <br /> fuel and left on site the hazardous waste drum. All primary containment for the UST system must be tight. <br /> Immediately have a properly licensed, trained, and certified contractor repair or replace the failed component. A permit <br /> may be required from the EHD. Provide a statement to EHD within 30 days on how the leak was corrected. <br /> This is a minor violation. <br /> 320 HSC 25290.1(c3), 25290.1(c3) Secondary containment not constructed to prevent water intrusion. <br /> Water was found in the Diesel STP (approximately 2 cups), Diesel Fill(approximately 1 cup) and Vent sumps <br /> (approximately 3 cups). Secondary containment shall be constructed to prevent any water intrusion into the system <br /> by precipitation, infiltration, or surface runoff. The service technician removed the liquid and returned the sensor to its <br /> proper location at the time of inspection. Immediately contact a properly licensed, trained, and certified contractor to <br /> address the water intrusion into the Diesel STP, Diesel Fill, and Vent sumps under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> "*Inspection conducted on March 25, 2015.Checklist was left on site at time of inspection. Official Inspection <br /> Report (OIR) completed and mailed certified to operator on March 27, 2015. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> Received by Inspector: Phone: Date: <br /> (initial): MICHELLE HENRY, Senior REHS (209)468-3454 03/25/2015 <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.