My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1800
>
1600 - Food Program
>
PR0161429
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2020 8:38:14 AM
Creation date
2/28/2020 4:05:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161429
PE
1626
FACILITY_ID
FA0016565
FACILITY_NAME
MASALATINA
STREET_NUMBER
1800
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
953375183
APN
22205002
CURRENT_STATUS
01
SITE_LOCATION
1800 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REV. DATE BY <br /> 8/1/18 HV <br /> SUBPANELD <br /> MOUNTING; RECESSED LOCATION: STORAGE WIRES 3 <br /> SUBPANEL D PHASES 1 AMPS: 200 VOLTS; 120/208 <br /> CIR DESCRIPTI❑N AMPS WATTS WATTS AMPS DESCRIPTION CIR <br /> 1 BEER DISPENSER 20/1 311 196 2011 BACK BAR 2 <br /> 3 CONVECTION 20/1 1920 1540 2011 PR❑OFER 4 <br /> OVEN <br /> 5 STEAM TABLE 20/1 1500 598 20/'1 SANDWICH TABLE 6 <br /> 7 SANDWICH TABLE 20/1 598 1058 20/'1 RADIANT HEATER 8 <br /> 9 REFRIGERATOR 20/1 472 1633 20/1 ICE MAKER 10 <br /> ELECTRICAL DOTES' 11 DISHMACHINE 20/1 1380 2760 20/1 FREEZER 12 <br /> 1. ALL ELECTRICAL WILL MEET C.E.C. 2016 & TITLE 24 STANDARDS <br /> 2. ALL MAIN FEEDERS TO BE XHHW AL. 13 BACK BAR 20/1 196 1500 2011 SMALL APPLIANCE 14 <br /> 3. MINIMUM BRANCH CIRCUT WIRING 12AWC THHN/THWN. c <br /> 15 SMALL APPLIANCE 2 1C7 <br /> 0/1 1500 <br /> 4. MINIMUM EMT CONDUIT/STEEL FLEX WILL BE 1/2" OR LARGER. 7 <br /> 5. WIRE 12AWG - GAWG THHN TO BE COPPER ONLY. 1 / 18 <br /> 6. FEEDER SIZE S #4 - 250 MCM XHHW TO BE AL. <br /> 7. ALL BRANCH FEEDERS TO BE EMT OR PVC SCHEDULE 40. 113 20 <br /> r(E)200A 8. FUSED DISCONNECTS TO HAVE TIME DELAY FUSES "FRN" "FRS" TYPE, <br /> MAIN I AND HAVE EXTERNAL OPERATED HANDLE. COMMERCIAL GRADE ONLY. 21 (E)125A <br /> ELECTRICAL IELECTRICALI <br /> (E)GAS I PANEL I 9. ALL GROUNDING TO SWITCHBOARDS, PANELS ETC., TO MEET TITLE 24 C.E.C. 23 �� ISUB-PPANELI <br /> METER I 10.MAX # OF CONDUCTORS IN EMT, PVC, FLEX, SHALL NOT EXCEED ALLOWABLE PER C.E.C. <br /> O 1 11.EMT, STEEL OR ALUMINUM FLES, SEALTITE WILL BE STANDARD FOR ALL WIRING METHODS. T❑TAL 7877 9285 TOTAL <br /> -�L 12.MINIMUM CLEARANCE WILL BE 36" AT ALL SWITCH GEAR LOAD CENTERS, <br /> ° UTILITY TRANSFORMER, ETC. PER C.E.C. TABLE 110-34(A) <br /> �;� / 13.MAX NUMBER OF OUTLETS (6) WITH MIN #12AWG AND 20amp SINGLE POLE CIRCUIT BREAKER <br /> ELECTRICAL LEGEND <br /> I w D MAX NUMBER OF OUTLETS 4 WITH MIN #12AWG AND 15amp SINGLE POLE CIRCUIT BREAKER O <br /> / w� 14.ALL OUTLETS EXPOSED TO EXTERIOR OR WET LOCATIONS WILL SYMBOL DESCRIPTION <br /> BE WEATHERPROOF TYPE. MANUFACTURED BY BELL OR EQUAL, �c� <br /> 15 TOBE <br /> SWITCH GEAR, <br /> A IS <br /> MANUFACTURED BY SQUARE DOR EQUAL ETC <br /> DUPLEX RECEPTACLE <br /> I \ 16.NO 1/2 SPACE C1RCUfT BREAKERS WILL BE USED. <br /> L17-7 L - - - J ` 17.ALL LIGHT FIXTURES WILL BE COMMERCIAL TYPE WITH "UL" LISTINGS. DEDICATED RECEPTACLE <br /> / 18.ALL CIRCUITS TO BE THHN WIRE. O <br /> 19.USE 75' C TABLE OF C.E.C. 310-16 FOR SIZING CONDUCTORS WHEN EIECI DUPLEX RECEPTACLE <br /> EQUIPMENT IS RATED AND LABELED FOR USE OF 75' C WIRE. <br /> 25PAmp - #12* THHN PER 20UAmp M OR CO2*1THHN PPER-CLAD ALUMINUM PANEL LOAD CALCULATIONS <br /> w 35 Amp - #10* THHN 30 Amp - #10* THHN <br /> -��. a. / <br /> 65 Amp - #6 THHN 50 Amp - #6 THHN Q <br /> DESCRIPTION UANTZTY DEMAND LOAD <br /> W <br /> / 85 Amp - #4 THHN 65 Amp - #4 THHN LIGHTS 8 4'2-TUBE FLUOR.AT 64W 1.25 6140 VA <br /> _w FL- <br /> 100 Amp - #3 THHN 75 Amp - #3 THHN <br /> - - J ! * UNLESS SPECIFICALLY PERMITTED IN 240.4(E) OR 240.4(0), THE OVERCURRENT PROTECTION 21 CLG MOUNTED AT 34W 1.25 8:93 VA <br /> SHALL NOT EXCEED 15A FOR 14 AWG, 20A FOR 12 AWG, & 30A FOR 10 AWG COPPER, OR 28 RECESSED AT 17W 1.25 5:95 VA <br /> 15A FOR 12 AWG & 25A FOR 10 AWG ALUMINUM & COPPER-CLAD ALUMINUM AFTER ANY 7 EXTERIOR AT 34W 1.25 2'98 VA <br /> A ' CORRECTION FACTORS FOR AMBIENT TEMPERATURE & # OF CONDUCTORS HAVE BEEN APPLIED. <br /> I/ 20.MOTOR DISCONNECTING MEANS C.E.C. 430--IX. RECEPTACLES 12 PLUGS @ 18OW 1.0 21,60 VA <br /> 11 21,ALL RECEPTACLES SHALL BE +15" A.F_F. MIN. UNLESS OTHERWISE NOTED, SIGN 1.0 12,00 VA u� <br /> 22.ALL SWITCHES, THERMOSTATS, ETC SHALL BE +48" A.F.F. MAX UNLESS OTHERWISE NOTED. EQUIPMENT BEERDISPENSER 115V/10/2.7A .65 2102 VA <br /> `\ ` +96" / 23.ALL EQUIPMENT GROUNDING SHALL CONFORM TO ARTICLE 250 OF THE C.E.C. LATEST EDITION, 2 BACK BARS 115V/10/1.7A .65 1:27 VA mow/ <br /> r A.F.F. 24.FINAL CONNECTIONS TO ALL DIRECT CONNECTED KITCHEN EQUIPMENT SHALL BE WITH U.L. EVAP COIL 1I5V/10/8.9A .65 665 VA <br /> APPROVED LIQUID TIGHT CONDUIT, PROVIDED W/ GROUND WIRE SIZED PER C.E.C. ARTICLE 250. CONDENSER 115V/10/1.3A .65 97 tVA <br /> \\ 1 /I 25.PANEL BOARD CIRCUIT BREAKERS USD AS SWITCHES MUST 8E APPROVED FOR FREEZER 230V/10/12A .65 17194 vA <br /> \ / SUCH DUTY AND BE OF THE "SWD" TYPE PER SECTION 408-111 OF THE C.E.C. EXHAUST FAN 115V/10/13,6A .65 1017 V <br /> 26.PROVIDE PARITY SIZED GREEN GROUND WIRE IN ALL CONDUITS/BRANCH CIRCUIT HOMERUNS. MAKE-UP AIR 208V/10/7.5A .65 1014 V <br /> AFF � W <br /> ` _ <br /> \ � � 27.VERIFY EXACT CONNECTION REQUIREMENTS, OUTLET TYPE, HEIGHT, & LOCATION OF ALL KITCHEN' CONVECTION OVEN 120V/10/16A .65 1248 VA\\ <br /> PROOFER 110VI10/14A •65 10101 VA <br /> \ , EQUIPMENT PRIOR ROUGH-IN. REFER TO EQUIPMENT SCHEDULE & FLOOR PLANS FOR MORE INFO, STEAM TABLE .65 0101 VA E T <br /> 120V/1 O/12.5A w <br /> 28.ALL CONDUIT PENETRATIONS IN RATED ASSEMBLIES SHALL 8E RATED AS PER U.L. RATINGS. 2 SANDWICH TABLES 115V/10/5.2A •65 3189 VA <br /> f 29.DO NOT INSTALL ANY OUTLETS BACK TO BACK IN STUD WALLS. RADIANT HEATER 115V/10/9.2A -65 6188 VA <br /> 30.ALL OUTLET BOXES IN RATED WALLS SHALL BE STEEL. REFRIGERATOR 1 I5V/10/4.1A .65 3107 VA <br /> \\ 115V/10/14.2A .65 10+62 VA <br /> 4 ` 31. RECEPTACLES IN I CONSTRUCTED WALLS BETWEEN OCCUPANCIES ICE MAKER . <br /> SHALL HAVE A MIN, <br /> OO F 24" HORIZONTAL SEPARATION. DISHMACHINE 115V/10/12A 65 897 VA <br /> 4 HVAC UNITS208 <br /> \ V/10/31.7A 1.0 15,2:28 VA 32.NOT MORE THAN 10 LIGHTS SHALL BE ❑N ANY LIGHTING CIRCUIT MICROWAVE 32,497 VA <br /> \ � l <br /> I / 33.W.P. GFCI CONVENIENCE RECEPTACLE SHALL / AIR CURTAIN <br /> BE INSTALLED R ROOF MOUNTED HVAC UNITS <br /> I � / F.L.A.@ 208/120V/10-TOTAL AMPS=90.2A <br /> DEDICATED FOR SMALL (E)125A <br /> APPLIANCES ELECTRICAL CT. <br /> suB-PANEL <br /> \ W � '4 <br /> \, p 00 <br /> DEDICATED E❑R <br /> SMALL \ FF�SII pQ O <br /> APPLIANCES <br /> Z �D W <br /> 00 <br /> w <br /> \ f <br /> ELECTRICAL PLAN. <br /> Scale 1/4" = F-Q" <br /> Job: Commercial <br /> Drawn By: H.V. <br /> Date 811118 <br /> APN 422-205-002 <br /> Sheet <br />
The URL can be used to link to this page
Your browser does not support the video tag.