Laserfiche WebLink
State o ' California DeparL.,,ent of Health Services % HML #: 902606 to <br /> Hazardous Materials Laboratory 902606 <br /> 2151 Berkeley Way, Berkeley, CA 94704 <br /> Phone: (415) 540-3003 or (ATSS) 571-3003 <br /> Collector's Name: ALAN ITO Auth. No. : HMG0614 <br /> Site of Sampling: QUICK BRAKE Activity : SURV & ENP <br /> 2325 WEST CHARTER Date Collected: 05/01/91 <br /> STOCKTON, 95207 Date Received: 05/28/91 <br /> Analytical Samples are digested with 1: 1 HNO3 (and 30% H202, and 1: 1 HC1, <br /> Procedure: if applicable) over a hot plate. The digestates are filtered <br /> EPA-SW 846 and made to final volume with deionized H2O. Metal analysis of <br /> the digest is by ICPAES (EPA #6010) . Units are mg/kg. <br /> Method: 3050 for solids; 3010 for liquids; 3005 for clean water. <br /> HML Number: 902606 <br /> Collecor's <br /> Sample No. : 2325-5-1-91-1 <br /> Sample Type: LIQUID <br /> As-Arsenic <0 . 20 <br /> Ba-Barium 4 . 51 <br /> Be-Beryllium <0 . 01 <br /> Cd-Cadmium 0 . 16 <br /> Co-Cobalt <0. 10 <br /> Cr-Chromium 0. 18 <br /> Cu-Copper 1. 95 <br /> Mo-Molybdenum 0. 98 <br /> Ni-Nickel 0. 25 <br /> Pb-Lead 0. 40 <br /> Se-Selenium <0 . 40 <br /> Tl-Thallium <0. 75 <br /> V-Vanadium <0. 13 <br /> Zn-Zinc 7 . 06 <br /> Notes: < = below detection limit of method. <br /> > = beyond standard calibration curve; <br /> (to be confirmed; an additonal report will follow) <br /> ICP Analyst, Date Coemist's Signature Date <br /> Merlyn Guzman Zenaida Odion, Chemist <br /> Milad S. Iskander, Supervisor Date <br />