My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_CASE 2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
26805
>
2900 - Site Mitigation Program
>
PR0522069
>
COMPLIANCE INFO_CASE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2020 11:00:08 AM
Creation date
3/3/2020 10:04:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
FileName_PostFix
CASE 2
RECORD_ID
PR0522069
PE
2960
FACILITY_ID
FA0015033
FACILITY_NAME
TAOC TRACY GRAVEL PITS
STREET_NUMBER
26805
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
24614001
CURRENT_STATUS
01
SITE_LOCATION
26805 S MACARTHUR DR
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CASE NARRATIVE <br /> STL SACRAMENTO PROJECT NUMBER G3K210162 <br /> SOLID,8290,Dioxins/Furans <br /> Sample(s): 1 <br /> There was strong matrix interference in this sample, which resulted in the loss of the 13C- <br /> OCDD internal standard, as well as yielded poor recoveries for the other internal standards. <br /> Quantitation by isotope dilution generally precludes any adverse effect on data quality due to <br /> low internal standard recoveries if signal-to-noise is greater than 10:1, which is achieved for <br /> all internal standards in the sample. <br /> This sample is reported from a lOg re-extraction in which extra cleanups were done to <br /> minimize matrix inteferences. A 1g re-extraction was also initiated but showed the same <br /> preparation matrix interferences. The 1OX re-extraction was analyzed at 5 X dilution and it <br /> was determined that although the 13C-OCDD internal standard has low recovery the signal to <br /> noise is acceptable. The 1 g extraction would have the same matrix issues and further <br /> processing of the 1 g extraction was stopped. Thus, the 10 g re-extracted sample at a 5 X <br /> dilution is the reported data for this sample. <br /> There were no other anomalies associated with this project. <br /> G3K210162 STL Sacramento(9 16)373-5600 1 of 14 <br />