Laserfiche WebLink
N 4 9 7 G'116 V�l)__� /7 1 = <br /> r <br /> CERTIFIC E <br /> Certified Services Company Day or Night <br /> 255 Parr Boulevard Telephone <br /> Richmond, California 94801 (415) 235-1393 <br /> For Erickson Inc. Tank No (s ) 4976Location Richmond 11-19-90 10.30 a.m. <br /> Date Time ' <br /> Test Method --Visual Gastech 1314 SMPN Last Product <br /> This is to certify that t have personally determined that the lank(s) in the following list on conditions existing at the time the inspection herein set forth was completed and is <br /> are in accordance with the American Petroleum institute and have found the condition issued subject to compliance with all qualifications and instructions <br /> of each to be in accordance with its assigned designation This certificate is based <br /> w Tank(s) <br /> Condition <br /> 1— Gal. Tank Safe For Fire Oxy 20.9% <br /> Remarks <br /> in, avent of any physical or atmospheric changes affecting the gas-free condition of undersigned This permit is valid for 24 hours if no physical or atmospheric <br /> the above tanks, or if in any doubt immediately stop all hot work and contact the changes occur <br /> Standard Safety Designation Safe for Fire Means that in the compartment so designated (a) The concentration <br /> Safe for Men Means that in the compartment or space so designated (a)The oxygen of flammable materials in the atmosphere is below 10 percent of the lower explosive <br /> content of the atmosphere is at least 19 5 percent by volume, and that (b) Toxic limit and that (b) In the Judgment of the inspector, the residues are not capable of <br /> materials in the atmosphere are within permissable concentrations and (c) in the producing a higher concentration than permitted under existing atmospheric conditions <br /> Judgment of the inspector, the residues are not capable of producing toxic materials in the presence of fire and while maintained as directed on the Inspector's certificate, <br /> under existing atmospheric conditions while maintained as directed on the Inspector's and further, (c)All adjacent spaces have either been cleaned sufficiently to prevent the <br /> certificate <br /> spread of fire,are satisfactorily inerted,or in the case of fuel tanks,have been treated as <br /> deemed necessar the inspector <br /> The undersigned representative acknowledges receipt of this certificate and understands t e con Itidhs and i iltations der which it was issued <br /> rtepre enta ive / Tule <br /> Inspector <br /> CPS875 <br />