Laserfiche WebLink
Underground Storage Tank Tracking records, and Certificates of Destruction are <br /> ' presented in Appendices B, C and D, respectively <br /> ' SOIL SAMPLING <br /> ' Soil samples were collected from the base of each tank excavation Soil samples were <br /> collected from both ends of each tank in accordance with Tri Regional Recommendations <br /> tFigure 3 illustrates the locations of soil samples collected within each excavation. <br /> ' Soil samples were collected with a backhoe. Approximately 3 inches of soil was rapidly <br /> scraped away from the surface of the soil in the backhoe bucket A sample was collected <br /> ' by driving a brass liner into the soil with a rubber mallet Both ends of the liner were <br /> covered with Teflon sheets and sealed with end caps The samples were labelled, recorded <br /> ' on a sham-of-custody, and placed in an ice chest cooled to 4°C for transport to an <br /> analytical laboratory. <br /> SOIL SAMPLE ANALYSIS <br /> Soil samples were analyzed in accordance with the analytical protocol presented on <br /> ' Table 2. Analytical results are presented in Table 3 Complete analytical reports are <br /> presented in Appendix A. <br /> 1 <br /> 1 <br /> 1 <br /> IhW-01(ka 1) Page 6 <br /> 1 <br />