* y <br /> 00lDgfcaf 7"ecluifw Inc. Page 5 <br /> Groundwater Monitoring Report <br /> Project No. 1030.2 <br /> March 18,2005 <br /> Before a sample was collected from each well, the water level was allowed to recharge to at <br /> least 80% of its initial level. MW-5 exhibited slow recharge during this event. Only one <br /> pruge volume was extracted from the well prior to sampling and the well recharged to 62% of <br /> its initial level. All water removed from the monitoring well and not used as a sample was <br /> ' placed in a 55 gallon DOT approved container that is properly labeled and temporarily stored <br /> on-site. <br /> ' An ISCOO peristaltic pump and dedicated tubing were used to collect each sample. Extreme <br /> care was exercised while collecting samples to prevent agitation of the water contained in the <br /> Waterra pump. With minimal sample aeration, water samples were transferred from the <br /> ' pump into 40-m1 VOA vials preserved with hydrochloric acid. All samples were checked for <br /> headspace bubbles, labeled, inserted into foam holders and placed into a cooled ice chest for <br /> transport to the laboratory. <br /> ' The sampling technician wore disposable gloves while collecting samples. <br /> les. <br /> P <br /> ' A chain of custody document, listing all samples collected and their intended analyses, <br /> accompanied the samples from field to the laboratory, thereby providing a means to track the <br /> movement of and ensure the integrity of the samples. <br /> The depth to groundwater data were submitted to GeoT <br /> racker as required under AB 2$86 on <br /> March 11, 2005. The confirmation code for the submittal is 8245274186. <br /> ' 2.2 Laboratory Analysis <br /> sis <br /> Groundwater samples collected on January 17, 2005, were delivered to Sherwood Labs <br /> Corporation of Hilmar, California (ELAN 1400) for analyses of: <br /> Benzene, Toluene,Ethyl Benzene, and Total Xylenes (BTEX) by EPA method 8020/8015 <br /> ' • Gasoline Range Organics (TPH-G) by EPA method 8020/8015 <br /> a MTBE by EPA method 8020/8015 <br /> a Positive results were confirmed by EPA method 8260 <br /> The results of the laboratory analyses are listed in Table 3 of Appendix A. Detection limits <br /> and analytical results are presented in Appendix B. <br /> The laboratory analytical data were submitted to GeoTracker as required under AB 2886 on <br /> March 11, 2005. The confirmation code for the submittal is 9393916249. <br />