for a total of 2,124 hours and removed approximately 33.53 pounds of TPHG. <br /> • SVE stem Operation and Maintenance <br /> Although the SVE system was operated in pulse mode during the majority of the fourth quarter 2005, the <br /> SVE system was operated on a full-time basis during the first quarter 2006 due to the detection of TPHG <br /> (310 mg/m3) observed in sample collected on December 7, 2005. Because influent concentrations have <br /> been close to or below laboratory reporting limits, SVE operation will be terminated. <br /> Stratus conducted six site visits during the first quarter 2006 to verify system operation, collect compliance <br /> discharge samples, and to conduct maintenance, if warranted. The SVE system was observed to be non- <br /> operating during the site visit conducted on March 28, 2006, probably due to a power outage. Based on <br /> the hour meter readings for March 6 and 28, 2006, the SVE system was likely shutdown on March 6, <br /> 2006. During the first quarter 2006, the SVE system has operated for approximate 1,350.3 hours. In the <br /> influent air sample collected on January 5, 2006, TPHG was reported at 17 mg/m , toluene was reported <br /> at 0.35 mg/m3, ethyl benzene was reported at 0.19 mg/m3, and total xylenes were reported at 1.23 mg/m3. <br /> Petroleum hydrocarbons or fuel oxygenates were not reported in any of the influent and effluent air <br /> samples collected during February and March 2006. The average influent airflow rate to the SVE system <br /> was observed at 68.60 cfm at an average applied vacuum of 39.50 inches of water column. Figure 4 <br /> presents change in influent concentrations of TPHG and the cumulative TPHG mass removed as a result <br /> of soil vapor extraction. As of March 1, 2006, a total of 4,137.73 pounds of TPHG has been removed from <br /> the subsurface beneath the site. The SVE system is operating as designed and is in compliance with the <br /> SJVAPCD permit requirements. <br /> If the petroleum hydrocarbon concentrations in extracted soil vapors continue to be low, Stratus will <br /> operate the SVE system in pulse mode. <br /> ATTACHMENTS: <br /> • • Table 1 Groundwater Elevation and Analytical Summary <br /> • Table 2 Groundwater Analytical Results for Oxygenates <br /> • Table 3 Operational Uptime and Flow Rate <br /> • Table 4 Flow Rates and Analytical Results of Air Sample Analysis <br /> • Table 5 Extraction and Emission Rates <br /> • Figure 1 Site Location Map <br /> • Figure 2 Groundwater Elevation Contour Map(First Quarter 2006) <br /> • Figure 3 Groundwater Analytical Summary (First Quarter 2006) <br /> • Figure 4 Cumulative Mass Removed and Concentrations of TPHG Vs Time <br /> • Appendix A Field Data Sheets <br /> • Appendix B Sampling and Analysis Procedures <br /> • Appendix C Certified Analytical Reports and Chain-of-Custody Documentation <br /> KAUSA Gasoline100651Qtrly120061USA_65_IQ06.DOC STRATUS <br />