Laserfiche WebLink
I <br /> Smith Technology Corporation j <br /> Quality Ammce/Quality Control Plan <br /> Revised FebruaryJ 995 <br /> is <br /> I <br /> 2.0 SAMPLE CONTAINERS i <br /> Groundwater samples will be placed in containers supplied by the analytical laboratory. Table 1 <br /> summarizes the required sample containers. <br /> Soil samples will be collected in either 8-ounce widemouth clear glass jars provided by the laboratory <br /> or in clean brass or stainless steel tubes (Table 1). Screw on caps will be fitted with teflon liners. <br /> Tubes will be tightly capped and sealed. <br /> 3.0 QU 'ALITY CONTROL FIELD SAMPLES i <br /> A QCprogram independent from the laboratory's program will be instituted. The program entails <br /> "blind" submittals to the laboratory of blank and duplicate samples. No spiked samples will be supplied <br /> r <br /> from the field;Ifor this investigation.. The laboratory in-house QC program will include analysis of <br /> spiked samples. All QC samples will be assigned independent sample numbers and made <br /> indistinguishable from non-QC samples. <br /> When sampling groundwater, travel blanks will be used to detect the introduction of contaminants <br /> during transportation from the field.to the laboratory. The travel blanks will be provided by the <br /> analytical laboratory. They will be taken to the field and accompany the collected groundwater <br /> samples to they, laboratory for analysis. The blanks will consist of deionized water and analytically <br /> confirmed organic-free water. The blank is numbered, packaged, and sealed in the same manner as the <br /> other samples. <br /> s <br /> W aAdmin\ShellslQAQC-97.DOC <br /> it <br /> 2 tl <br /> I1 I <br /> I <br /> II <br /> :i <br />