Laserfiche WebLink
CAMBRIA <br /> Table 1. Ground Water Pumping Test Results - Shell-branded Service Station, <br /> 341 Main Street, Ripon, California <br /> Test K, Hydraulic Conductivity T,Transmissivit <br /> Constant Rate Test Pumping -Well EW-1 <br /> Cooper-Jacob (unconfined) on MW-1 6 8E-01 ft/min 3 5E-01 cm/s 4 3E+00 ft /min <br /> Theis recovery (unconfined) on MW-1 6 9E-01 ft/min 3 5E-01 cm/s 4 0E+00 ft2lmin <br /> Theis (unconfined) on MW-1 2 7E-01 ft/min 1 4E-01 cm/s 1 7E+00 ft2lmin <br /> Cooper-Jacob (unconfined) on EW-2 5 6E-01 ft/min 2 8E-01 cm/s 5 1 E+00 ft2/min <br /> Theis recovery (unconfined) on EW-2 2 6E-01 ft/min 1 3E-01 cm/s 2 4E+00 ft2/min <br /> Theis (unconfined) on EW-2 5 3E-01 ft/min 2 7E-01 cm/s 4 8E+00 fe/min <br /> Cooper-Jacob (unconfined) on MW-2 1 0E-01 ft/mm 5 2E-02 cm/s 1 5E+00 ft2/min <br /> Theis recovery (unconfined) on MW-2 9 6E-01 ft/min 4 9E-01 cm/s 1 4E-01 ft2/min <br /> Thus (unconfined) on MW-2 1 0E-01 ft/mm 5 1 E-02 cm/s 1 5E-01 ft2/min <br /> Theis recovery (unconfined) on EW-1 1 2E-02 ft/mm 6 0E-03 cm/s 1 6E-01 ft2lmin <br /> -Step-Drawdown Test-_Pumping Well EW-1 <br /> Theis &Jacob Recovery on EW-1 5 1 E-03 ft/min 2 6E-03 cm/s 7 1 E-02 ft2lmin <br /> Cooper&Jacob on MWA 8 0E+00 ft2lmin <br /> Neuman on MW-1 8 7E-01 ft/min 4 4E-01 cm/s 5 0E+00 ft2/min <br /> Theis on MWA 6 6E+00 ft /min <br /> Average 4 2E-01 ftlmin 21 E-01 curls 3 1 E+00 fe/min <br /> stdev 3 4E-01 1 7E-01 2 6E+00 <br /> I <br /> i <br />