Laserfiche WebLink
Laencaster.Holland ,l.aboratories Ex lanation <br /> z 4 Symbols and Abbreviations <br /> p <br />�. rhe following defines cornmon symbols and abbreviations used in reporting technical data: <br /> BMQL Below Minimum Quantitation Level <br /> N.D. none detected <br /> TNTC ' Too Numerous To Count MPN Most Probable Number <br /> tU International Units CP Units cobalt-chloroplatinate units <br /> umhoslcm micromhos/cm NTLInephelometric turbidity units <br /> ' C degrees Celsius F degrees Fahrenheit <br /> Ib. pound(s) <br /> meq milliequivalents <br /> g grams) <br /> Kg kilogram(s) <br /> ug microgram(s) mg milligram(s), <br /> ml milliliter(s) I liter(s) '3 <br /> j m3 cubic meter(s) ul microliter(s) <br /> j < less than-The number following the sign is the limit of quantitation,the smallest amount of analyte which can be <br /> {' reliably determined using this specific test. <br /> > greater than <br /> J estimated value—The result-is>_the Method Detection Limit(MDL)and <the Limit of Quantitation (LOQ). <br /> PPM parts per million-One ppm is equivalent to one milligram per kilogram (mg/kg),or one gram per million grams. For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/!), because one liter of water has a <br /> weight very close to a kilogram. For gases or vapors, one ppm is equivalent to one microliter of gas per liter of gas. <br /> ii <br /> ppb parts per billion <br /> Dry weight Results printed under this heading have been adjusted for moisture content. This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture. All other results are reported <br /> i on an as-received basis. <br /> i U.S. EPA CLP Data Qualifiers: <br /> Organic Qualifiers Inorganic Qualifiers <br /> e <br /> A TIC is a possible aldol-condensation product B Value is<CRDL, but AOL . <br /> k B Analyte was also detected in the blank E Estimated due to interference <br /> { C Pesticide result confirmed by GC/MS M Duplicate injection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions(MSA)used T <br /> the instrument for calculation <br /> } N Presumptive evidence of a compound (TICs only) U Compound was not detected ; <br /> P Concentration difference between primary and W Post digestion spike out of control limits <br /> confirmation columns X25% Duplicate analysis not within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0.995 <br /> X,Y,Z Defined in case narrative <br /> { <br /> Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis. <br /> Measurement uncertainty values,as applicable, are available upon request. <br /> Tests results relate only to the sample tested. Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample. Unless the sample analyzed is truly representative of the bulk of material involved, the <br /> test results will be meaningless. If you have questions regarding the proper techniques of collecting samples, please contact <br /> us. We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff. This report shall:not be reproduced except in full,without the written approval of the laboratory. <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work,:we warrant the accuracy of test results for the sample as submitted. <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> IMPLIED. WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY. IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL,OR INCIDENTAL DAMAGES INCLUDING,BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER. <br /> -"ABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF. SUCH <br /> -AMAGES. We accept no legal responsibility for the purposes for which the client uses the test results. No purchase order or other order <br /> for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client. <br /> 3768.02 <br /> ' 3 <br /> w. <br />