Laserfiche WebLink
i • <br /> ,• AA <br /> NORCAL <br /> Pacific Environmental Group, Inc <br /> July 10, 1996 <br /> Page 5 <br /> (Plate 2) shows the variations of the vertical magnetic gradient tfiroughout the site <br /> These variations include several high magnitude variations around the perimeter of the <br /> site, as well as in the center of the survey area We interpret the magnetic gradients <br /> along the southeast border as representing effects caused by above ground storage <br /> drums, light poles, and metal bumper poles in the survey area The circular gradients <br /> located in the northwest and southwest corners represent effects from metal poles <br /> severed at the ground surface Four areas with anomalously steep gradients that <br /> could not be associated with effects from above ground cultural features are located <br /> in the center of the survey area and are considered anomalous, as described above <br /> These anomalies are labeled A through E, as shown on Plate 2 <br /> Anomaly A is characterized as a high amplitude bi-polar anomaly with a peak to <br /> trough value of 450 nanoteslas per meter (nT/m) This anomaly represents effects <br /> from the known UST mentioned above We obtained GPR data over this anomaly to <br /> identify the surface trace of the UST This data resolved reflection patterns within <br /> • the upper two to three feet that are characteristic of disturbed subsurface materials <br /> However, no hyperbolic patterns characteristic of a UST were evident on the records <br /> Therefore, the UST is buried deeper than the detection limas of the GPR The EMLL <br /> investigation over this anomaly resolved buried metal in an area of approximately 4 <br /> by 6 ft These dimensions approximately correspond to a 550 gallon UST The EMLL <br /> method also resolved the surface trace of an undifferentiated utility trending from the <br /> UST vault lid to the concrete pad associated with a former building This utility is <br /> shown on Plate 1 <br /> Anomalies B and E are characterized as high amplitude mono-polar anomalies with <br /> values of approximately 400 nT/m Anomalies C and D are characterized as bi-polar <br /> with values of 250 nT/m Since these values are close to those resolved over <br /> Anomaly A (known UST), it is possible that they may represent additional small <br /> UST's Furthermore, It has been our experience that anomalies of these magnitudes <br /> and areal extents may also be due to metal sources such as buried debris and/or <br /> utility vaults The GPR data obtained over these anomalies resolved localized <br /> hyperbolic reflection patterns that are typical of small isolated objects and utility lines <br /> The GPR data do not indicate large hyperbolic signatures within the upper two to <br /> three feet that could represent an UST Therefore, the source of these anomalies <br /> may be very localized or buried deeper than the detection limits of the GPR The <br /> results of the EMLL investigation resolved the surface trace of several Undifferentiated <br /> utility alignments in this area, as shown on Plate 1 The surface trace of these <br /> . utilities, as well as the possible extent of the known UST, were marked on the ground <br /> surface with spray paint <br />