Laserfiche WebLink
1 <br /> HK)W EN111170NMENTAL 117c. <br /> • Field Log <br /> Project Name Fuller Mobile Nome Park <br />' Client WHF, Inc Date 311196 <br /> Sample Location I D MW 3 <br /> Sampler Jeff Webb <br />' Groundwater XX Other _ <br /> Casing Diameter 2 inch XX 4 inch 6 inch Other <br /> Calculated Purge Vol (gal) 266 <br /> Depth of well (feet) 2659 Actual Purge Vol (gal) 825 <br /> Depth to water(feet) 1032 <br /> FIELD MEASUREMENTS <br /> VOLUME P H E C TEMPERATURE <br /> TIME (gal ) (units) (ushos/crn) (Degrees C) <br /> 334 275 506 Y 1965 195 <br /> 340 550 505 1864 192 <br /> 346 825 506 1918 199 <br /> PURGE METHOD 2"Bladder Pump <br /> SAMPLE METHOD 2" Disposable Bailer <br /> Remarks ODOR <br /> Signature <br /> IVOLUMES PER UNIT LENGTH SELECTED CONVERSION FACTORS <br /> WELL CASING DIAMETERS <br /> Volume per unit length To Convert Into Multiply <br /> Well casing Cubic <br /> I D (inches) Gal/FT FT/FT Ft of Water Lbs/5q In 04335 <br /> Lbs/Sq In Ft of Water 2 307 <br /> Cubic Feet Gallons 748 <br /> 16 00918 00123 Gallons Liters 3 785 <br /> 2 01632 00218 Feet Meters 03048 <br /> 4 06528 00873 Inches Centimeters 254 <br /> 6 1 469 01963 <br /> HKM ENVIRONMENTAL INC <br /> l 10274 Jalapa Way LaGrange Ca 95329 (209)852-9551 <br />