Laserfiche WebLink
H iV f-N11117J-7 A,1ENTAL 117c. <br />' Field Log <br /> Project Name Fuller Mobile Home Paris <br />' Client WHF Inc Date 311196 <br /> Sample Location I D MW 7 <br /> Sampler Jeff Webb <br />' Groundwater XX Other <br /> Casing Diameter 2 inch XX 4 inch 6 inch Other <br /> Calculated Purge Vol (gal ) 215 <br /> Depth of well (feet) 21 48 Actual Purge Vol (gal) 675 <br />' Depth to water(feet) 832 <br /> FIELD MEASUREMENTS <br />' VOLUME P H E C TEMPERATURE <br /> TIME (gal ) (units) (ushos/cm) (Degrees C) <br />' <br /> 1220 225 537 219 — 214 <br /> 1225 450 536 215 201 <br /> 1235 675 541 224 203 <br /> I <br /> PURGE METHOD 2"Bladder Pump <br /> SAMPLE METHOD 2" Disposable Bailer <br /> Remarks <br /> Signature <br /> IVOLUMES PER UNIT LENGTH SELECTED CONVERSION FACTORS <br /> WELL CASING DIAMETERS <br /> IVolume per unit length To Convert Into Multiply <br /> Well casing Cubic <br />' I D (inches) Gal/FT FT/FT Ft of Water Lbs/Sq In 04335 <br /> L bs/Sq In Ft of Water 2 307 <br /> Cubic Feet Gallons 748 <br /> I <br /> 15 00918 00123 Gallons Liters 3 785 <br /> 2 01632 00218 Feet Meters 03048 <br /> 4 06528 00873 Inches Centimeters 254 <br /> 6 1 469 01963 <br /> • HKM ENVIRONMENTAL INC <br /> 10274 Jalapa Way LaGrange Ca 95329 (209)852-9551 <br /> I <br />