t t <br /> moi/ Lr/ <br /> 6.0 SAMPLING AND DRILLING EQUIPMENT DECONTANIINATION <br /> All equipment used for drilling and sampling will be decontaminated prior to use. All equipment <br /> used for collection of more than one sample, such as bailers and spoons, will be decontaminated <br /> between each use to prevent cross contamination between samples. Drilling equipment will be <br /> decontaminated prior to commencing drilling at each hole. Well construction materials will be <br /> cleaned as necessary, prior to installation. <br /> Equipment and well material decontamination will be conducted on an impermeable surface and <br /> all decontamination effluent will be contained. All surfaces of the equipment will be thoroughly <br /> decontaminated using a steam cleaner. The equipment will be placed on a drying rack for air <br /> drying. The decontamination water will be stored in containers certified for hazardous materials <br /> storage and disposed of in an approved manner. <br /> Sample equipment to be used for pesticides and organic analysis will be washed in a <br /> nonphosphate detergent (Alconox or equivalent) and rinsed with tap water and deionized water. <br /> 7.0 FIELD EQUIPMENT CALIBRATION AND MAINTENANCE <br /> The following measuring equipment may be used during the Remedial Investigation. Equipment <br /> is grouped by field activity. Calibration procedures and frequency are listed for each piece. <br /> • Soil Borings and Well Dimensions- <br /> Steel and coated cloth tape. Calibration: none. <br /> • Water Level Measurements in Wells- <br /> Steel surveyors tape. Calibration: manufacturer supplied temperature correction <br /> will be applied as applicable for field conditions. Electrical well sounders. <br /> Calibration: check against steel surveyor's tape. <br /> • Organic Vapors- <br /> Photoionization detector. Calibration: Daily logged field calibration using a <br /> isobutylene standard as per manufacturers instructions. <br /> • Groundwater pH Measurements- <br /> Digital pH meter. Calibration: standard pH solutions of 4,7, and 10 will be <br /> utilized for daily logged field calibration according to manufacturers instructions. <br /> • Electrical Conductivity- <br /> Electrical conductivity meter. Calibration: factory-calibrated annually and <br /> periodically calibrated against laboratory prepared standard calibration solution. <br /> • Water Temperature- <br /> Mercury or digital thermometers. Calibration: one-time factory-calibrated. <br /> • Combustible Gas/Oxygen- <br /> Combustible gas/oxygen meter calibration: Factory calibrated, field calibrated <br /> monthly, zeroed daily according to manufacturers instructions. <br /> 4 <br />