Laserfiche WebLink
TABLE 6 - SVE - INFLUENT LOG <br /> 151 South Main Street, Manteca California <br /> SJVUAPCD Permit Unit N-3920-1-0 <br /> influent avg ow avg operation total cumulative total percentutilized <br /> Date ppmv ppmv rate lbs/day I period lbs/period lbs removed comment period period total <br /> a <br /> 01/10/99 37 4 100 01 800 1 2 6174 8 10000% 5639% <br /> 01/17/99 37 4 100 01 700 09 6183 7 10000% 5728% <br /> 01/24/99 37 4 100 01 700 09 6192 7 10000% 5814% <br /> 01131/99 29 3 100 01 700 08 6201 7 10000% 5897% <br /> 02/07/99 37 3 100 01 700 08 6209 7 1 10000%1 5976% <br /> Analyses performed with a Fox Model TVA-1000A Toxic Vapor Analyzer The TVA 1000-A features both FID and PID detectors Far the analyses <br /> cited above, only FID analyses are performed to quantify concentrations of Total Petroleum Hydrocarbons as Gasoline(TPHg) Prior to <br /> the start of each analysis, (at least once per day), the TVA is calibrated according to Foxboro procedures using both zero gas and 100 ppm methane <br /> *** Laboratory Analysis reported as 8,400 mg/m3 <br /> i <br />