Laserfiche WebLink
�S <br /> Lancaster. <br /> Labo <br /> rator�es Analysis Report <br /> 2425 New Holland Pike,PO Box 12425.Lancaster.PA 17605-2425•717-656-2300 Fax:717-656-2681 Ww*lancaslerlabs-com <br /> Page 3 of 3 <br /> 5� <br /> Quality Control Summary <br /> Client Name: ChevronTexaco Group Number: 925041 C <br /> Reported: 01/05/05 at 10:17 AM <br /> Surrogate Quality Control <br /> LCSD 103 <br /> MS 106 <br /> Limits: 57-146 <br /> Analysis Name: BTEX+5 Oxygenates+EDC+EDB+ETOH <br /> Batch number: Z043521AA <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-de 4-Bromofluorobenzene T <br /> 4429661 91 91 103 93 <br /> Blank 92 93 102 92 <br /> LCS 91 92 102 97 <br /> Ms 92 92 102 98 ' <br /> MSD 91 91 103 97 <br /> Limits: 81-120 82-112 85-112 83-113 <br /> Analysis Name: BTEX+5 Oxygenates+EDC+EDB+ETOH <br /> Batch number: Z043531AA 1 <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 4429662 91 91 103 92 <br /> Blank 92 94 102 92 <br /> LCS 91 93 102 98 - <br /> MS 91 93 102 98 1 <br /> MSD 92 92 103 98 J <br /> Limits: 81-120 82-112 85-112. 83-113 <br /> I� <br /> J <br /> J <br /> *-Outside of specification -� <br /> (1) The result for one or both determinations was less than five times the LOQ. <br /> (2) The background result was more than four times the spike added. <br /> • <br />