' PRESENTATION OF CONE PENETRATION TEST DATA <br /> i <br /> 1.0 INTRODUCTION <br /> ' This report presents the results of a Cone Penetration Testing (CPT) and in situ <br /> groundwater sampling program carried out at the Chevron site located in Ripon, CA <br /> The work was performed on February 4th, 2003 The scope of work was performed as <br /> directed by Secor personnel <br /> 2.0 FIELD EQUIPMENT & PROCEDURES <br /> ' The Cone Penetration Tests (CPT) were carried out by GREGG 1N SITU, INC of <br /> Martinez, CA using an integrated electronic cone system The CPT soundings were <br /> performed in accordance with ASTM standards (D 5778-95) A 20 ton capacity cone <br /> was used for all of the soundings (figure 1) This cone has a tip area of 15 cm2 and <br /> friction sleeve area of 225 cm2 The cone is designed with an equal end area friction <br /> ' sleeve and a tip end area ratio of 0 85 <br /> The cones used during the program recorded the following parameters at 5 cm depth <br /> intervals <br /> - Trp Resistance (qc) 4 <br /> 10 - Sleeve Friction (fs) <br /> - Dynamic Pore Pressure (U) <br /> ' The above parameters were printed simultaneously on a printer and stored on a <br /> computer diskette for future analysis and reference <br /> The pore water pressure element was located directly behind the cone tip The pore <br /> water pressure element was 5 0 mm thick and consisted of porous plastic Each of the <br /> elements were saturated in silicon oil under vacuum pressure prior to penetration Pore <br /> pressure dissipations were recorded at 5 second intervals when appropriate during <br /> pauses in the penetration <br /> A complete set of baseline readings was taken prior to each sounding to determine <br /> temperature shifts and any zero load offsets Monitoring base line readings ensures <br /> that the cone electronics are operating properly <br /> The cones were pushed using GREGG IN SITU's CPT rig, having a down pressure <br /> capacity of approximately 20 tons Two CPT soundings were performed The <br /> penetration tests were carried to depths of approximately 120 feet below ground <br /> surface Test locations and depths were determined in the field by Secor personnel <br /> 1 <br />