Laserfiche WebLink
Page 17 <br /> XII DECONTAMINATION PROCEDURES <br /> A Equipment (Sampling, Construction, Etc.)Decontamination (Solvents used, Equipment <br /> used, Method of Disposal) Attach site decontamination map as necessary. <br /> ui ment shall be cleaned using TSP rinsed twice with tap water and rinsed final!y with distilled <br /> water Rinseate will be stored in 55 gallon drums. <br /> B Personnel Decontamination(Solvents used, Method of solvent disposal, Include <br /> decontamination method of PPE and disposal of PPE) Attach site decontamination map as <br /> necessary. <br /> Performed b,rinsing with TSP and notable water Contaminated PPE will be disposed of in <br /> a waste containment du=ster <br /> C Investigation derived material disposal. <br /> 1 Drill cuttings/well water Stored on site. Soil cuttinga stored in DOT 17-H steel <br /> drums Water stored in DOT 17-H steel drums Disposal at certified landfill facilities soil or <br /> by pumptruckwater depending on lab results Material ma also be remediated on site if <br /> on site remediation of soil or groundwater is chosen cleanup oltmon <br /> 2. Decontamination Solutions Stored along with investigation well water in drums <br /> 3 Other PPE disposed of in trash duml2ster. <br /> I <br /> I <br /> i <br /> Legible and understandable precautionary labels must be affixed to containers of contaminated <br /> clothing, debris, waste, raw materials and mixtures <br /> I <br /> I <br /> I <br />• I <br /> I <br /> Parker Environmental Services, 4185 Rialto Court, Pittsburg, CA 94565-6116 <br /> Phone (510) 439-1024 Fax (510) 439-2566 <br />