= me = = = <br /> Stockton Site <br /> Hydraulic Conductivity Values <br /> Hvorslev Analysis <br /> Well Number Test Number Effective Screen Inside Screen Length of Aquifer To (min) Hydraulic Conductivity <br /> Radius, R (ft ) Radius, r (ft-)— Screened,-L (ft) K (ftldaY)— <br /> Mw-1 <br /> )MW-1 Falling Head 1 0 252 00833 13 0.36 421 <br /> Falling Head 2 0 252 00833 13 0 35 433 <br /> Rising Head 1 0 252 00833 13 0 21 7 22 <br /> Rising Head 2 0 252 00833 13 0 26 5 83 <br /> MW-8 Falling Head 1 0 306 0 167 11 8 84 0 74 <br /> Falling Head 2 0 306 0 167 11 8 87 0 74 <br /> Rising Head 1 0 306 0 167 11 1 66 3 94 <br /> Rising Head 2 0 306 0 167 11 1 55 4.22 <br /> MW-9 Falling Head 1 0 306 0 167 15 5.52 0 94 <br /> Falling Head 2 0 306 0 167 15 546 0 95 <br /> Rising Head 1 0 306 0 167 15 409 1 27 <br /> Rising Head 2 0 306 0 167 15 4071 1 28 <br /> About The Data <br /> MW-01 is a 2" well, whereas MW-8 and M <br /> It should be noted that the data from MW-8 and MW-9 may be more reliable than that from MW-01 because <br /> the ratio of the screen to the borehole is closer than than of MW-01 With a 2" well, it is harder to screen out <br /> the effects of the filter pack upon the slug test <br />