RESNA <br /> SITE SAFETY PLAN <br /> ❑ Confined Space Entry (follow RESNA's Confined Space Entry Procedures) <br /> ❑ Other -explain hazard and mitigation <br /> EXPOSURE MONITORING <br /> All sample results will be recorded in the RESNA exposure log. Log copies are filed in the job file, and <br /> in all site personnel's medical file, and maintained in the job file. All sampling instruments will be <br /> calibrated per the manufacturers instructions on a daily basis. <br /> *Note calibration gas and any unusual calibration settings in the "monitoring equipment" column. <br /> "*Include monitoring for health hazards, explosion hazards, etc. <br /> Monrtorng Hazard Sample Sample;; Action <br /> Egwpnileft Mon*tored Locat,on Frequency Level Action <br /> OVM/PID Organic Vapors Immediate Periodic 20 ppm* Level C w/1/2 <br /> Vicinity of Monitoring or full face <br /> Personnel respirator <br /> OVM/PID Organic Vapors Immediate Periodic >200 ppm Evacuate <br /> Vicinity of Monitoring Site <br /> Personnel <br /> " Benzene is not specifically monitored for with a OVM so any vapor reading at 20 ppm must require <br /> 1/2 face respirator. <br /> Identify sample locations on site map. <br /> PAGE 6 <br />