Laserfiche WebLink
i <br /> i16 5.0 PERSONAL PROTECTION <br /> Level Of Protection Planned Level D Personal Protection Equipment(PPE)includes <br /> coveralls, (dry), leather(wet) neoprene steel toe and shank boots,(wet/dry) eye protection, hard <br /> hats and nitnle gloves <br /> Condition To Upgrade To Level C 100 PPM total hydrocarbons <br /> Level C Contingency Equipment. Level C(PPE)includes(dry/wet) tyvek suits with over <br /> boots attached to the tyvek suits with duct tape, nitrile gloves,(dry) leather(wet)neoprene boots <br /> ' with steal toe and shank,(dry/wet)eye protection,hard hat, and full face air purifying respirator <br /> with MSA Hydrocarbon cartridge filter or equivalent <br /> ' Accommodations Bathroom facilities will be provided on site In the event that food is not <br /> readily accessible,food will be brought in SSO will be in charge of appropriate breaks and rest <br /> period <br /> 6.0 DECONTAMINATION <br /> Personal Decontamination Procedures Informal (wash, nnse) <br /> Emergency Decontamination Remove all contaminated clothing Decontaminate personnel, <br /> using established decontamination procedures Call ambulance and notify appropriate emergency <br /> facilities <br /> Equipment Decontamination Steam cleaning of all equipment before leaving site at <br /> designated area <br /> ' Instruction For Disposal Of Contaminated Rinsate Rinsate will be handles as hazardous <br /> until analytical results are available <br /> ' 7.0 EMERGENCY PLANNING <br /> Police 911 Fire Department 911 <br /> Health Department Fire responsible <br /> ' Local Hospital Attached map illustrates route to this hospital <br /> 5of6 <br />