April 14, 1993 Project No. EK-6032-2 <br /> EXPOSURE MONITORING <br /> All sample results will be recorded in the FSE exposure log. Log copies are filed in the job file, <br /> and in all site personnel's medical file, and maintained in the job file. All sampling instruments <br /> will be calibrated per the manufacturer's instructions on a daily basis. <br /> *Note calibration gas and any unusual calibration settings in the "monitoring equipment"column. <br /> "Include monitoring for health hazards,explosion hazards,etc. <br /> Monitoring Hazard Sample Sample Action <br /> ui meet Monitored Location Frequency Level Action <br /> Over borehole 35 ppm for Cease drilling operations& <br /> Petroleum -in geologist 15 ruin.,or move up-wind of site until <br /> OVM h position 30 minutes 100 ppm OVM readings decrease <br /> Identify sample locations on site map <br /> 6 <br />