Laserfiche WebLink
MPDS-UN0187-08 <br /> May 30 1996 <br /> Page 6 of 6 <br /> • Table 3 <br /> Summary of Laboratory Analyses <br /> Water <br /> GramdWatox <br /> Elevafton TPJI as n l y- <br /> DaW well a# (red) 'Gasolitle Iet att Tclm psi xyltao <br /> 11/17/94 U-1 -3631 5,000 540 12 250 840 <br /> U-2 -36 10 360 88 <10 3 8 45 <br /> U-3 -3623 42,000 9,600 1,800 2000 4,600 <br /> 8/19/94 U-1 -3623 5,000 960 17 380 1,200 <br /> U-2 -3622 870 150 12 33 87 <br /> U-3 -35 87 51,000 9,700 1,300 2,100 5,600 <br /> d Sequoia Analytical Laboratory has Identified the presence of MTBE at a level above or equal <br /> to the taste and odor threshold of 40 pg/L in the sample collected from this well <br /> <# Non-detectable at or above stated detection limit <br />• Results are in micrograms per liter (µg/L), unless otherwise indicated <br /> Note The detection limit for results reported as ND by Sequoia Analytical Laboratory <br /> is equal to the stated detection limit times the dilution factor indicated on the <br /> laboratory analytical sheets <br /> Prior to August 1, 1995, the total purgeable petroleum hydrocarbon(TPH as gasoline) <br /> quantification range used by Sequoia Analytical Laboratory was C4 - C12 Since <br /> August 1, 1995, the quantification range used by Sequoia Analytical Laboratory <br /> is C6 -C12 <br />