Laserfiche WebLink
I1AY-24-19?5 13;28 Fp,CH GEOLOGICAL TECHNICS TO 4646947 P.03 <br /> Page tm <br /> May 23, 1995 <br /> Bok)w is a fist of materials and services SSG will provide: <br /> mom Qty Description <br /> 1. 1 C&drical thermal oxidizer capable of 254 Sdrn of process effluent mounted on a <br /> traler. <br /> 2. 2 Type Kthermocouples with type 304 stainless steel them-sawells ('I dual: 1 single). <br /> 3. 1 GornbusWone incineration burner rated at 500 MBtuihr with a 230 volt, 1 phase <br /> combustion air blower. <br /> 4. 1 30 gakn capacity fiiterlseparator with pump. <br /> 5_ 1 Factory Mutual(FIVI) style gas valve train Including: <br /> 5a. 2 Apollo ball valves. <br /> 5b. 1 Main gas pressure regulator. <br /> 5c. 1 I loneywell high gas pressure switch. <br /> 5d. 1 t loneywelt low gas pressure switch. <br /> 5e. 1 Hogs) Il safety shutoff valve and operator. <br /> 5f. 1 Butterfly valve with macrrrting bracket and linkage for rrsaduladng control motor. <br /> 5g. 1 Honeywell modulating control mortar. <br /> W i Adjustable Cmiting orifice. <br /> 6. 1 Complete pilot gas valve train and pilot burner assembly. <br /> 7. 1 Flame gas valve train including: <br /> 7a. 1 Low gas pressure switch (Prove blower is operating). <br /> 7b. 1 Honeywell safety shutoff valve and operator. <br /> 8. 1 Vacuum compressor including a 230 volt, single phase motor wdh a maximum rating l <br /> of 7.5 horsepower. <br /> 9. 1 Complete UL Listed control panel including: <br /> 9a. 1 NEMA 12 enclosure and panel. <br /> 9b. 1 Drip visor and 13"x 8"window. <br /> 90. 1 Westinghouse circuit breakerwith disconnect mechanism. <br /> 9d. 2 Aden Bradley motor starters, <br /> 9e. 1 Honeywell UDC 2000 high temperature lama#. <br /> 9f. 1 Honeywell UDC 2000 temperature controller. <br /> 9g, 1 Honeywell electronic flame safeguard o ontroler with <br /> ultra-violet flame scanner. <br /> 9h. 1 Rustrark strip chart temperature recorder. <br /> 9i. 1 Purge timer. <br /> 3j. 1 Panel nomenclature. <br /> 9k. lot Wiring and assembly. <br /> 10. 1 Traiier with a rated capacity of 5,300 pounds Including rights, hitch and 4 jack stands <br /> (One per comer). <br /> 11. 1 Heat e)*Mnger including installation capable of preheating the incoming process <br /> gas to 600 F. <br /> 12. 1 Each unit Wil be trial tested at SSG facility. <br /> 13. 1 Option 1: U*st mounted in a stainless steel removable assembly including extra <br /> them-K=uple and rep3ecament section for thermal operations, <br /> 14. 1 Option 2: e0 Scfm Q 20" Hg direct drive skid mounted blower. inlet & outlet <br /> silencers, motor and controls mounted in a NEMA 12 enclosure. <br />