Laserfiche WebLink
L. <br /> A site map (Generalized Site Plan, Plate 2) showing the <br /> tanks, piping systems, adjacen", streets and buildings, <br /> septic tanks and leach fields, and underground <br /> utilities. <br /> Results Of tank tests or initial site work completed. <br /> • Estimates of liquid leaked into the environment. <br /> History of site use. <br /> Local tOPOgraVhy, geology, nearby streams, depth to, <br /> groundwater. <br /> Proximity of private -Dr municipal wells and irrigation <br /> wells within 2,000 feet. <br /> Location of nearby septic tanks and underground public <br /> utility lines. <br /> Distance to adjacent buildings and their water znd <br /> sewer lines. <br /> proposed sampling methodology. <br /> The purpose of the next phase of additional work is to <br /> investigate the limits of soil and groundwater <br /> contamination. The results of the preliminary assessment <br /> investigation would be presented in a Problem Assessment <br /> Report, which will present the data used to indicate the <br /> t * extent of contamination, calculated groundwater surface <br /> elevation maps, soil stratigraphy data, preliminary aquifer <br /> parameters as necessary to define remedial alternatives, and <br /> a discussion of appropriate remedial alternatives. <br /> When the Problem Assessment Report is completed and <br /> accepted by regulatory agencies, a Final Remedial Plan (FRP) <br /> will be required after appropriate discussions with <br /> and- Tabora-t-ory_ <br /> regulatory <br /> ROGER FOOTT ASSOCIATES, INC <br />