Laserfiche WebLink
The groundwater samples collected from all three of the groundwater monitoring wells contained <br /> detectable concentrations of petroleum hydrocarbons The groundwater sample collected from <br /> MW-1 contained 6,300 µg/I of TPH-as-diesel, 8,600 µg11 of TPH-as-gasoline, 30 µg11 of benzene, <br /> ' 1,300 µg11 of ethylbenzene, and 53 µg11 of xylenes The groundwater sample collected from MW-2 <br /> contained 1,100 µg11 of TPH-as-diesel and 220 µg/l of TPH-as-gasoline The groundwater sample <br /> collected from MW-3 contained 6,200 [.g/l of TPH-as-diesel, 2,700 µg11 of TPH-as-gasoline, 13 <br /> µg/1 of benzene, 1 2 µg/I of toluene, 230 µg/1 of ethylbenzene, and 12 µg/I of xylenes The <br /> gasoline oxygenate compounds and 1,2-DCA were not detected in any of the groundwater <br /> samples The groundwater analytical results are summarized in Table 2 The concentrations of <br /> TPH-as-diesel, TPH-as-gasoline and benzene are posted on Figure 4 The laboratory report is <br /> included as Appendix A <br /> 9 <br />