Laserfiche WebLink
PAR-Eckert Cold Storage, Manteca,CA <br /> November 25,2002 <br /> Page 6 <br /> Table ] -Groundwater Sample Laboratory Analytical Results (September 30, 2002) <br /> GASOLINE OXYGENATES/ADDITIVES <br /> B T E X TPH-G <br /> MTBE Other Gasoline Oxygenates/Additives <br /> ' Detection Limits: 0.5 0.5 0.5 1.0 0.05 0.5 0.5-5.0 <br /> µg/1 µPQ ! g/l µg/1 mg/l µg/l PgA <br /> Analytical Method: 8260B 8260E 8260B 8260B 8015M 8260B 8260B <br /> Sample I.D. <br /> 3471A-MW1-9130/02 1,400 6.9 220 100 11 10 <5.0-<50 <br /> 3471 A-MW3-9/30/02 41 1.5 48 19 1.2 3.1 <0.5-<5.0 <br /> 3471A-MW4-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 <0.5 1,2-DCA 3.14 <br /> 3471A-MW5-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 1.2 <0.5-<5.0 <br /> 3471 A-MW6-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 <0.5 <0.5-<5.0 <br /> 3471A-MW7-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 <0.5 <0.5-<5.0 <br /> 3471 A-MW8-9/30/02 480 2.3 51 27 5.4 9.2 <2.0-<20 <br /> ' 3471A-DW-9/30/02 1 <0.5 1 <0.5 1 <0.5 <1.0 <0.05 <0.5 <0.5-<5.0 <br /> Note: MW-2 was not sampled as damage to the well casing during installation of the well prevents placement of bailers and pumps down <br /> • the well. <br /> Units: Analytical: <br /> mg/L=milligrams per liter=parts per million(ppm) 8,T,E,X=benzene,toluene,ethyl benzene,total xylenes <br /> µg/L=micrograms per liter=parts per billion(ppb) TPH-G=total petroleum hydrocarbons quantified as gasoline <br /> Gasoline oxygenatesladditives= methyl tertiary butyl ether(MTBE),ethanol, <br /> tertiary butanol,di-isopropyl ether(DWE),ethyl tertiary butyl ether(ETRE), <br /> tertiary amyl methyl ether (TAME), 1,2-dibromoethane (EDB), 1,2- <br /> dichloroethane(1,2-DCA) <br /> ♦=all other oxygenates/additives were not detected at or above the laboratory <br /> ' reported detection limits <br /> One groundwater sample was collected from each of the ten Hydropunch borings (HP-1 through HP-10) <br /> and three separate groundwater samples (CPT-1, CPT-2-S1, S2, and S3) were collected at discrete <br /> intervals from each CPT boring pair and submitted for laboratory analyses. Samples were collected from <br /> the following depth intervals: 22.5-26.5 feet bgs (HP1); 21-25 feet bgs (HP-2 through HP-9); 26-30 feet <br /> bgs (HP-10); 39-43, 83-87, and 100-104 feet bgs (CPT-1-S1, S2, and S3); and, 21-25, 52-56, and 85-89 <br /> feet bgs (CPT-2-S1, S2, and S3). Laboratory analytical results indicate that TPH-G, BTEX, and selected <br /> gasoline oxygenates/additives were not detected at or above the laboratory reported detection limits in <br /> the groundwater samples collected from the CPT and Hydropunch borings with the following exceptions: <br /> (1) MTBE was detected above the laboratory reported detection limit in the groundwater samples <br /> collected from borings HP-1, HP-2, HP-4, and HP-8; (2) 1,2-DCA was detected above the laboratory <br /> reported detection limit in the groundwater samples collected from borings HP-1, HP-2, and HP-4; (3) <br />•' TPH-G and BTEX were detected above the laboratory reported detection limits in CPT-1-S 1 and S2; and, <br /> (4) TEX was detected above the laboratory reported detection limits in CPT-1-S3. <br />' MTBE was detected by EPA Method 8260B in the groundwater samples collected from borings HP-1, <br /> HP-2, HP-4, and HP-8 at concentrations of 1.6 pg/l, 2.0 FLg/l, 1.8 4g11, and 0.7 µg11, respectively. 1,2- <br /> DCA was detected by EPA Method 8260E in the groundwater samples collected from borings HP-1, Hp- <br /> 2, and HP-4 at concentrations of 1.3 Ltg/i, 1.0 }tg/l, and 1.3 pg/1, respectively. THP-G and BTEX were <br /> � s <br />' �•1� CONDOR <br />