Laserfiche WebLink
VT <br /> T Interim Soil Remediation Work'Phan V� <br /> Former MEL BOKIDES PETROLEUM FACILITY <br /> 219I:=Navy Drive;Stockton;California <br /> 1.0. •INTRODUCTION' :z <br /> At the request of Mr:Nick Bokides of Mel Bokides Petroleum;Inc.,Advanced GeoEnvironmental, <br /> Inc. (AGE) has prepared the enclosed Interim Soil RemediationW.ork Plan for the property located <br /> at 2191 Navy Drive, Stockton,,California(the site); The location of the site is illustrated on figure.- f <br /> r 1. A plan of the site is illustrated on Figure <br /> Based onanalytical and visual data from the underground storage tank.(UST) system removal'from <br /> the site,'.An.interim remediation of hydrocarbon-impacted--soil in the mid product,-line trench and <br /> dispenser areas appears is warranted"The,purpose of this scope,of work.is to excavate a limited <br /> volume-of.hydrocarbon-irripacted,soil;collect'and analyzed soil samples,:as to remove'Soil'in'the . .. <br /> unsaturated zone of the-subsurface that is'a potential contributing sources of the Hydrocarbon impact _ <br /> to the saturated zone ai the site,'away from the'significantly-impacted UST excavation. <br /> This Work Plan is prepared in accordance,with Central Valley Reg ional'WaterA.Quality Control. <br /> Board (CVRWQCB) guidelines and San Joaquin County Public Health Services Environmental;- t <br /> Health Division(PHS-EHD)'guidelines for the-subsurface rernediation of underground storagetank," ;= <br /> (UST) sites. <br /> 2.0. BACKGROUND <br /> - The site is located in an incorporated industrial/commercial.aea of west.Stockton; California, on.� <br /> Navy.Drive,(Figure 1). The,site j ,presently vacant <br /> 2.1. SITE DESCRIPTION �_ # _ <br /> The majority of the site consists_of unpaved'dirt area.�Orie structure, consisting of an-office building. F. <br /> and a shop building, are located on the property-(Figure 2).No wells are located;on th&'property.-The <br /> surrounding sites are.used.for,storage, auto dismantling and-a'-rail road right-of way is located north.- . a . <br /> of the site. - <br /> -�•k t of - of{{ <br /> 2.2. UNDERGROUND STORAGE TANK ACTIVITY AND-REMOVAL, "I <br /> AGE has been informed.tHat eight USTs;dispensers and piping were active on the site for•almost . <br />•'` - twenty years from'the early 1980s-.to'the late 1990s. The UST-removal s'we're'witnessed by a ='� <br /> representative'of the PHS-EHD. Tracking'record's for-waste-r6m'oved•from-the' UST should have <..r. <br /> been supplied to.the PHS-EHD:in.the.UST removal report: History:of the.UST use, tank tests, ,#;.. <br /> Ad►axcedGeoEnvironrieentel,In"e. y • 3 <br />