My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2020 4:31:56 PM
Creation date
3/25/2020 11:38:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility ABC Foodmart Facility 713 N. EI Dorado, Stockton Inspection A r 25, 2013 <br /> Name: Address: Date: p <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1 =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M1) <br /> Other Violations <br /> 999 X Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUM O VI LATIONS <br /> CLASS I, LASS I o INOR-Notice toom I <br /> This is a report of the Routine and Monitoring System Certification inspection conducted at the <br /> referenced facility by San Joaquin County Environmental Health Department (EHD). The following is a <br /> Repeat Violations: 104, 311, and Minor-Notice to Comply: 313 <br /> 104. (Repeat) Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. A copy of current financial responsibility <br /> documents were provided to EHD during this inspection. Violation has been corrected on site. <br /> 311. (Repeat) The diesel line leak detector failed to detect a leak when tested. All line leak detectors <br /> shall be capable of detecting a 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, <br /> trained, and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) <br /> and obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br /> immediately, there is a possibility that the UST system may be red tagged to prevent fuel inputs. <br /> 313. The 87-octane spill container failed when tested. All spill containers shall have a minimum capacity <br /> of five gallons and be capable of containing a spill or overfill until it is detected or cleaned up. <br /> Immediately contact a properly licensed, trained, and certified contractor to repair or replace the spill <br /> container under permit and inspection of the EHD. <br /> NOTES <br /> Assisted owner in complying with AB 2286 requirement to submit electronic data of CUPA hazardous <br /> material programs to the statewide portal California Environmental Reporting System (CERS). <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> Iq T S CILI S UBJECT TO REINSPECTIONAT ANYTIME AT EHD'S CURRENT HOURLY RATE. <br /> Insp t Received By. Title. <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />