Laserfiche WebLink
FILE COPY <br /> San Joaquin County <br /> �� " .� Environmental Health Department DIRECTOR <br /> Donna Heran, REHS <br /> 600 East Main Street <br /> �I1�l' P 9s `I Stockton' California 95202-3029 PROGRAM COORDINATORS <br /> .; I Robert McClellon, RENS <br /> Jeff Carruesco, REHS. RDI <br /> \ .r Kasey Foley, REHS <br /> \�i F o R�� Website: www.sjgov.org/ehd Linda Turkatte. REHS <br /> July 5, 2011 Phone: (209) 468-3420 <br /> Fax: (209) 464-0138 <br /> Carl Wayne Henderson <br /> APEC <br /> PO Box 55,105 <br /> Stockton, CA 95205 <br /> Re: ABC Food Mart SR0062.600 <br /> 713 N. EI Dorado, Stockton, CA 95202 <br /> The San Joaquin County Environmental Health Department(EIAD) has completed the review of <br /> the application for a permit to repair/adjust the diesel leak detector, and replace gaskets with <br /> Pomeco P31 1­G on the fill sumps and spill buckets on the underground storage tank (UST) <br /> system at the above noted address, and the subsequent amendment of the permit application to <br /> replace the 87 annular sensor with a Veeder-Root Model 303 sensor. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Jeff Wong at (209) 468-0335 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Sensor functionality: 'Functionality of the monitoring system must be verified to <br /> ensure that monitoring has been restored to meet the requirements of Title 23 <br /> California Code of Regulations and the Health & Safety Code. <br /> b. Leak detector test: Leak detector must be tested to confirm that the device can <br /> detect a leak of 3 gallons per hour at 10 psi. <br /> c. Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic <br /> test (or'equivalent). Proper drainage must also be verified. <br /> d. Verify fill sumps are properly sealed to prevent water intrusion. <br /> Please be aware that the facility cannot operate the UST system prior to the EHD <br /> inspection and approval. <br /> 4. If concrete will be broken near the UST, a secondary containment test must be <br /> performed on the UST once concrete is poured in accordance with the manufacturer's <br /> guidelines. <br />