PH October 10, 1990 <br /> leo N ��� <br /> Moss &Craig <br /> 1919 Grand Canal Blvd. <br /> Stockton, CA 95207 <br /> Attn: Mr. Ken Reiner <br /> Re: Weber Ranch Level II Work Plan <br /> BACKGROUND <br /> At your request,pH7 Environmental will perform a Level II investigation at the Weber <br /> Ranch development located at the northeast corner of March and West Lanes in Stockton, <br /> Ca (refer to Figures 1 &2). We understand that the lender for the Weber Ranch Ofice Park <br /> is concerned with possible sur cial pesticide residues and potential petroleum hydrocarbon <br /> contamination from a BP gas station located at 1206 East March Lane on the southwest <br /> corner of March and West Lanes. Currently, there is no reason to suspect that the <br /> underground tanks at the station either have leaked or are leaking,but soil and groundwater <br /> sampling are a requirement for funding the project. A level I Environmental Assessment <br /> will be conducted concurrently with the Level II investigation. <br /> The target substances of the Level II investigation will be petroleum hydrocarbons in the <br /> subsurface soil and groundwater and pesticides in the surficial soils. <br /> The site has recently been graded and no underground utilities have yet been installed <br /> Borehole locations have been placed a minimum of twenty five (25)feet from curb lines to <br /> prevent interference with public utilities. There are no septic tanks,leachfields,buildings, <br /> or underground utilities (including water, sanitary sewer,or storm sewer) on the site. <br /> BOREHOLE DRILLING AND SOIL SAMPLING <br /> Two test borings will be performed with a permit from San Joaquin County Public Health <br /> Services (refer to Figure 3). Drive samples will be screened with a portable volatile organic <br /> analyzer(VOA). Positive results will be submitted to Clayton Environmental Services in <br /> Pleasanton, CA for TPHg and BTEX analyses.The test borings will be backfilled to the <br /> surface with neat Portland cement. <br /> Between drilling locations the drilling auger and samplers will be steam cleaned to reduce <br /> the possibility of cross contamination between boreholes. Cuttings generated during <br /> drilling will be disposed on-site if VOA readings are negative. Otherwise,cuttings will be <br /> stockpiled on plastic adjacent to the borehole and covered with plastic sheeting until receipt <br /> of the analytical results. Based on the analytical results,pH7 Environmental will provide <br /> recommendations to Moss & Craig on disposal options for the soil cuttings. Disposal of all <br /> cuttings will be the responsibility of Moss &Craig. <br /> 18211 Bollinger Canyon Road San Ramon CA 94583 415-831-1957 Telecopy 415-838-2151 <br />