• Taare 7 •
<br /> East System-Ozone Injection System Operating Data
<br /> Stockton Terminals Technical Committee
<br /> 2526 West Washington Street,Stockton,California
<br /> System Status Hourmeter Readings(hours) Percent Operation I Electric
<br /> On Ozone ! Compressor Compressor Meter
<br /> On Arrival Departure System Generator Running Load Period Cumulative Reading
<br /> Date Notes On/O On/O hours hours hours hours % % kWhr
<br /> 9/21/0413:45 a OffOn 0 0 4 2 NA NA -
<br /> 101141041 :10 On On 505 505.0 521.0 442.0 92% 92°h -
<br /> 11/3/048:10 On On 983 983.0 922 790 100% 96% 19,265
<br /> 12/8/049:00 On On 1,824 1,824.0 1,777 1,827 100% 98% -
<br /> L2117/O6145
<br /> 059:15 On On 2,498 2,498.0 - - 100% 98% -
<br /> 059:00 On On 3,151.12 3,151.12 3,090 2,661 80% 94% -
<br /> /0512:50 b On Off 3,483.25 3,483.25 3,509 2,953 98% 94% -
<br /> /05 0:00 b Off Off 3,483.25 3,483.25 3,509 2,953 0% 53% -
<br /> /059:44 c Off On 3,483.00 3,483.25 3,509 2,953 0% 41% 33,821
<br /> /0514:00 On On 3,849.00 3,849.00 3,876 3,271 100% 43% -
<br /> /0512:00 On On 4,375.00 4,375.00 4,402 3,740 100% 46%
<br /> /0510:35 Off On 4,544.50 4,544.50 4,571 3,907 59% 47% 44,361
<br /> /0512:44 d On Off 5,194.00 5,194.00 5,221 4,554 100% 50% 44,359
<br /> /0512:00 Off On 5,194.00 5,194.00 5,221 4,554 0% 50%
<br /> /0514:45 On On 5,556.15 5,556.02 5,683 4,909 100°� 52% 54,946
<br /> /069:30 On On 6,427.52 6,427.39 6,226 5,476 81% 54% 63,667
<br /> /0610:45 On On 6,931.59 6,932.16 6,731 5,909 100% 56% 68,764
<br /> /06 0:00 On On 7,080.00 7,079.00 6,879 6,036 100% 57% 70,261
<br /> /0613:00 a Off Off 7,436.17+T,435 59 - - 95% 58% 74,886
<br /> Reporting Period: First Quarter 2006 12/13/05 to 3110106
<br /> Period Hours Operational: 1,880
<br /> Period Percent Operational: 90%
<br /> Period Pounds Ozone Injected' 392
<br /> Cumulative Pounds Ozone Injected': 1549
<br /> Estimated Period Pounds Hydrocarbons Destroyed': 131
<br /> Estimated Total Pounds Hydrocarbons Destroyed*: 516
<br /> Definitions:
<br /> NA Not applicable
<br /> Data not collected or unavailable
<br /> Notes:
<br /> a System startup.
<br /> b System shutdown.
<br /> c System integrity verified and restarted.
<br /> d Onsite to shutdown system due to damaged conduit during fence installation. Conduit repaired by fence contractor.
<br /> e System down on arrival due to a fire in the oil separator,system remains shutdown until replaced.
<br /> "The pounds of ozone injected is determined assuming 5 pounds per day of ozone is generated and the complete amount is injected.
<br /> 'The pounds of hydrocarbons destroyed is determined assuming for every 3 pounds of ozone injected 1 ound of hydrocarbon is destroyed.
<br /> IASTTGStockton\08MtSTTC Ozone Injection 08M Work book 1006.)ds Page 1 of 1