Laserfiche WebLink
• Taare 7 • <br /> East System-Ozone Injection System Operating Data <br /> Stockton Terminals Technical Committee <br /> 2526 West Washington Street,Stockton,California <br /> System Status Hourmeter Readings(hours) Percent Operation I Electric <br /> On Ozone ! Compressor Compressor Meter <br /> On Arrival Departure System Generator Running Load Period Cumulative Reading <br /> Date Notes On/O On/O hours hours hours hours % % kWhr <br /> 9/21/0413:45 a OffOn 0 0 4 2 NA NA - <br /> 101141041 :10 On On 505 505.0 521.0 442.0 92% 92°h - <br /> 11/3/048:10 On On 983 983.0 922 790 100% 96% 19,265 <br /> 12/8/049:00 On On 1,824 1,824.0 1,777 1,827 100% 98% - <br /> L2117/O6145 <br /> 059:15 On On 2,498 2,498.0 - - 100% 98% - <br /> 059:00 On On 3,151.12 3,151.12 3,090 2,661 80% 94% - <br /> /0512:50 b On Off 3,483.25 3,483.25 3,509 2,953 98% 94% - <br /> /05 0:00 b Off Off 3,483.25 3,483.25 3,509 2,953 0% 53% - <br /> /059:44 c Off On 3,483.00 3,483.25 3,509 2,953 0% 41% 33,821 <br /> /0514:00 On On 3,849.00 3,849.00 3,876 3,271 100% 43% - <br /> /0512:00 On On 4,375.00 4,375.00 4,402 3,740 100% 46% <br /> /0510:35 Off On 4,544.50 4,544.50 4,571 3,907 59% 47% 44,361 <br /> /0512:44 d On Off 5,194.00 5,194.00 5,221 4,554 100% 50% 44,359 <br /> /0512:00 Off On 5,194.00 5,194.00 5,221 4,554 0% 50% <br /> /0514:45 On On 5,556.15 5,556.02 5,683 4,909 100°� 52% 54,946 <br /> /069:30 On On 6,427.52 6,427.39 6,226 5,476 81% 54% 63,667 <br /> /0610:45 On On 6,931.59 6,932.16 6,731 5,909 100% 56% 68,764 <br /> /06 0:00 On On 7,080.00 7,079.00 6,879 6,036 100% 57% 70,261 <br /> /0613:00 a Off Off 7,436.17+T,435 59 - - 95% 58% 74,886 <br /> Reporting Period: First Quarter 2006 12/13/05 to 3110106 <br /> Period Hours Operational: 1,880 <br /> Period Percent Operational: 90% <br /> Period Pounds Ozone Injected' 392 <br /> Cumulative Pounds Ozone Injected': 1549 <br /> Estimated Period Pounds Hydrocarbons Destroyed': 131 <br /> Estimated Total Pounds Hydrocarbons Destroyed*: 516 <br /> Definitions: <br /> NA Not applicable <br /> Data not collected or unavailable <br /> Notes: <br /> a System startup. <br /> b System shutdown. <br /> c System integrity verified and restarted. <br /> d Onsite to shutdown system due to damaged conduit during fence installation. Conduit repaired by fence contractor. <br /> e System down on arrival due to a fire in the oil separator,system remains shutdown until replaced. <br /> "The pounds of ozone injected is determined assuming 5 pounds per day of ozone is generated and the complete amount is injected. <br /> 'The pounds of hydrocarbons destroyed is determined assuming for every 3 pounds of ozone injected 1 ound of hydrocarbon is destroyed. <br /> IASTTGStockton\08MtSTTC Ozone Injection 08M Work book 1006.)ds Page 1 of 1 <br />