Laserfiche WebLink
• TaDfe 9 • <br /> West System-Ozone Injection System Operating Data <br /> Stockton Terminals Technical Committee <br /> 3003 Navy Drive,Stockton,California <br /> System Status Hourmeter Readings hours) Percent Operation Electric <br /> On Ozone Compressor Compressor Meter <br /> On Arrival Departure System Generator .Running Loatl Period' Cumulative Reading <br /> Data Notes On/0 (On/Off) hours hours hours hours % / kWh, <br /> 11/15/04 9:00 a,b Off _ On 1.0 1.0 3.0 1.0 NA NA <br /> 12/8/0412:00 On On 573 573 485 573 100% 100% <br /> 115/059:15 On On 1,226 - 1,226 979 1,226 98% 100% <br /> 2181059:00 On On 1,862 1,862 1,862 1,500 78% 91% <br /> 2/12/0512:30 c On Off 2,131 2,130 2,324 1,785 79% 90% <br /> W010512:30 d Off On 2,131 2,130 2,324 1,785 0% 41% <br /> 6/21/05 11:00 a On Off 2,153 2,152 2,346 11805 98% 41% <br /> SM310514:00 f OR On 2,153 2,152 2,346 1,805 0% 41% <br /> 7/12105 11:30 9 On Off 2,581 2,581 2,712 2,155 94% 45% <br /> 8/2510510:40 In Off On 2,581 2,581 2,712 2,156 0% 38% 27055 <br /> 918/057:30 I On On 2,915 2,915 3,125 2,425 100% 41% 31342 <br /> 9128/057:30 f Off On 2,919 j4,741 <br /> ,919 3,129 21429 1% 38% <br /> 10120/0510:00 On On 3,447 ,447 3,657 2,854 100% 42% <br /> 11/1/05x.0:00 On- -44% -38593 -- - - <br /> 11/28/0510:00 On On 4,383 ,383 4,593 3,621 100% 48% <br /> 12/13/0511:20 On On 4,742 4,952 3,918 99% 50% 48752 <br /> 113/0611:30 c On Off 5,247 ,246 5,457 4,334 1 100% 53°h <br /> Reporting Period:First Quarter 2006(12/13/05 to 01/03/061 <br /> Period Hours Operational: 505 <br /> Period Percent Operational: 100% <br /> Period Pounds Ozone Injected': 105 <br /> Cumulative Pounds Ozone Injected*: 1093 <br /> Estimated Period Pcunds Hydrocarbons Destroyed*: 35 <br /> Estimated Total Pounds <br /> Hydrocarbons Destroyed*: 364 <br /> Definitions: <br /> NA Not applicable <br /> - Data not collected or unavailable <br /> Notes: <br /> a System startup. <br /> b Manifolds 7 and 8 are off due to hydrocarbons volatilizing at the ground surface when injecting to those well sets. <br /> c System shutdown due to high water. <br /> d System restart&reprogramed.All A zone on simultaneously then all B zone on simultaneously.Manifolds 7&8 back on. <br /> e System shutdown due to drilling. <br /> f System restart. <br /> g System shutdown due to back pressure regulator seals damaged. <br /> h Back Pressure Regulator repaired and system restarted. <br /> i Manifold 2 pneumatic actuator replaced&9 offline due to mntime error. <br /> 'The pounds of ozone injected is determined assuming 5 pounds per day of ozone is generated and the complete amount is injected. <br /> 'The pounds of hydrocarbons destroyed is determined assuming for every 3 pounds of ozone injected 1 pound of hydrocarbon is destro ed. <br /> lASTTC-Stockton\Q&WTTC Ozone Injection O&M Workbook IQ06.xis Page 1 of 1 <br />