Laserfiche WebLink
rMONITORING AND REPORTOPROGRAM NO.R5-2005-XXXX • -3 - <br /> SHELL <br /> 3 - <br /> SHELL OIL PRODUCTS US,BULK FUEL TERMINAL <br /> STOCKTON,SAN JOAQUIN COUNTY <br /> Semi-annual groundwater monitoring reports shall be submitted to the Regional Board by <br /> 1 February (discussion of third and fourth quarter events) and 1 August (discussion of first and <br /> second quarter events) until such time as the Executive Officer determines that the reports are no <br /> longer necessary. Each semi-annual report shall include the following minimum information: <br /> (a) a description and discussion of the groundwater sampling event and results, including trends <br /> in the concentrations of pollutants and groundwater elevations in the wells, how and when <br /> samples were collected, and whether the pollutant plume(s) is delineated; <br /> (b) field logs that contain, at a minimum,water quality parameters measured before, during, and <br /> after purging, method of purging, depth of water, volume of water purged, etc.; <br /> (c) groundwater contour maps for all groundwater zones, if applicable; _ <br /> (d) isocontour pollutant concentration maps for all groundwater zones, if applicable; <br /> (e) a table showing well construction details such as well number, groundwater zone being <br /> monitored, coordinates (longitude and latitude), ground surface elevation, reference <br /> elevation, elevation of screen, elevation of bentonite, elevation of filter pack, and elevation of <br /> well bottom; <br /> (f) a table showing historical lateral and vertical (if applicable) flow directions and gradients; <br /> (g) cumulative data tables containing the water quality analytical results and depth to <br /> groundwater; <br /> (h) a copy of the laboratory analytical data report; <br /> (i) if applicable, the status of any ongoing remediation, including cumulative information on the F <br /> mass of pollutant removed from the subsurface, system operating time, the effectiveness of <br /> the remediation system, and any field notes pertaining to the operation and maintenance of <br /> the system; and <br /> (j) if applicable, the reasons for and duration of all interruptions in the operation of any <br /> remediation system, and actions planned or taken to correct and prevent interruptions. <br /> An Annual Report shall be submitted to the Regional Board by 1 February of each year. This T <br /> report shall contain an evaluation of the effectiveness and progress of the investigation and <br /> remediation, and maybe substituted for the second semi-annual monitoring report. The Annual <br /> Report shall contain the following minimum information: <br /> (a) both tabular and graphical summaries of all data obtained during the year; <br /> (b) groundwater contour maps and pollutant concentration maps containing all data obtained <br /> during the previous year; <br />