NRR-22-1995 18:56 GRADIENT P.031106 <br /> • • <br /> Surrogate spike recoveries to assess accuracy of the results relative to laboratory <br /> performance and specific sample matrix. <br /> Field duplicate BPDs to assess precision of the results relative to field sampling <br /> techniques and the specific sample matrix and representativeness of the sample aliquot <br /> to the area sampled. <br /> Instrument tunes and calibrations to assess accuracy and sensitivity of the results relative <br /> to the instrument performance. <br /> Internal standards to assess accuracy relative to instrument performance and specific <br /> sample matrix of the results. <br /> Quantitation limits to assess sensitivity of the results. <br /> Accuracy <br /> Holding limes <br /> The holding times were reviewed to ensure the accuracy of the reported results;exceeded holding <br /> times may cause biased low results due to sample degradation. The chain-of-custody (COC) for <br /> 5 of the samples indicated that the samples were preserved with hydrochloric acid (HCl); <br /> however, the other two COCl did not indicate presence or lack of sample preservative. During <br /> the data usability assessment, Gradient assumed that all the samples were preserved with HCl. <br /> The required analytical holding time for preserved volatile samples is 14 days from date of <br /> sample collection. <br /> The following sample analyses at the dilutions listed were not performed within 14 days of <br /> sample collection: MW462, MW4-62 1:10 (12/9/94), MW4-62 1:10 (12/12/94), MW4.62 <br /> 1:100, MW4-62 1:200, MW5-51, MW5-51 1:10, MW5-DUP, MW5-DUP 1:10, MW5-EB, <br /> MW6-51 1:10, MW6-51 1:1000, MW7-60 1:100, MW9-60 1:10 (12/8/94), MW9-60 1:10 <br /> (12/12/94), MW10-54 1:10(12/8/94), MW1O-54 1:10(12/12/94), MWI1-60 1:40, MWII-DUP <br /> 1:40, MW 12-60 1:10, MW 12-60 1:100, MW 12-60 1:200, and MW21-110 1:100. The positive <br /> and nondetect results in these sample analyses have been qualified as estimated (J and UJ, <br /> respectively), and may be biased low. These results are usable as estimated values. <br /> Surrogate Spike Recoveries <br /> The surrogate spike recoveries were reviewed to assess the accuracy of the results relative to <br /> laboratory performance and specific sample matrix. All surrogates recovered within the QC <br /> limits of 80-120%, with the exception of surrogate bromofluorobenzene (BFB) that recovered <br /> below the QC limits in sample analyses MW1-55, MWI-DUP, MW4-62 1:10 (12/9/94), MW9- <br /> 60,MW9-60 1:10(12/8/94),MW10-54, MWIO-54 1:10(12/8/94),MW12-60 1:200, MW30-EB, <br /> TB5, and TB6. All positive and nondetect results in these sample analyses have been qualified <br /> as estimated (J and UJ, respectively) and may be biased low, as indicated by low surrogate <br /> recoveries. These results are usable as estimated values. <br /> g:\projeots\dq\9504I0U.mom 2 Gradient Corporation <br />