Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ZMT INC 1 1010 SHAW RD, STOCKTON October 01, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> OBSERVATION: A complete modified contingency plan was not posted at the facility. <br /> REGULATION GUIDANCE: The business operator must post the following information next to telephones or in <br /> areas directly involved in the generation and accumulation of hazardous waste: the name and emergency <br /> telephone number of the emergency coordinator, the location of fire extinguishers and spill control material, and the <br /> telephone number of the fire department unless the facility has a direct alarm. <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by filling out a modified contingency <br /> plan. No further action is required to correct this violation. <br /> This is a repeat violation, Class II. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers <br /> were: <br /> -One blue plastic approximately 50 gallon drum of used oil was observed without the words"Hazardous Waste", <br /> generator name&address, and physical state. <br /> -One black plastic 5 gallon bucket of used bearing grease was observed without a hazardous waste label. <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator, hazardous properties, physical state, composition <br /> (contents), accumulation start date <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by filling out hazardous waste labels and <br /> putting them on the containers. No further action is required to correct this violation. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> Documents provided during inspection: Hazardous waste labels, hazardous waste labeling guidance, flyer for <br /> free CUPA classes, modified contingency plan <br /> Waste streams found: <br /> -Used Oil <br /> -Used Bearing Grease <br /> Notes: Forklift maintenance is performed by Valley Forklift. Facility had less than 100kg of hazardous waste on <br /> site at the time of the inspection. Hazardous waste is taken to SJC HHW facility. <br /> FA0018663 PR0527552 SCO01 10/01/2019 <br /> EHD 22-01 Rev.9/20/2019 Page 4 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />