My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
7676
>
2900 - Site Mitigation Program
>
PR0001228
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2020 3:58:11 PM
Creation date
3/31/2020 3:49:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0001228
PE
2951
FACILITY_ID
FA0004069
FACILITY_NAME
BREUNERS
STREET_NUMBER
7676
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
08102013
CURRENT_STATUS
02
SITE_LOCATION
7676 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Harding Lawson As8o618te5 <br /> 8.0 RECOMMENDATIONS <br /> Based on the work performed to date and our conclusion that a minimum <br /> potential exists for adverse impacts to the groundwater, HLA recommends that no <br /> further remediation subsurface exploration be co`nducted'at the`site and Breuners; <br /> L: petition the SJCDEH and RWQCB for case closure. f A <br /> To complete this project, HLA recommends that the soil stockpiles 11a disposed <br /> and the excavation be backfilled. On the basis of the laboratory <br /> a Y analysis of the stockpile <br /> samples, HLA recommends that the soil be transported to the BFI Class III landfill in <br /> Livermore, California, for disposal. q <br /> The excavation should be backfilled with aggregate subbase material (ASB) to a <br /> depth of approximately 8 to 10 inches below grade. The ASB should placed in thin lifts, <br /> moisture conditioned and compacted to 90 percent or greater relative compaction. The <br /> excavation should be brought to 2 inches below grade by placing 6.to 8 inches of <br /> aggregate base material over the ASB and compacting it to a minimum 95 percent <br /> relative compaction. Paving the backfilled excavation should be conducted by placing <br /> and compacting approximately 2 inches of asphalt concrete over the base material. <br /> A copy of this report should be submitted to the SJCDEH and RWQCB for <br /> approval. <br /> If the SJCDEH and RWQCB approve Breuners petition for case closure, and/or <br /> HLA's recommendation for soil disposal and excavation backfilling, HLA can make the <br /> 'arrangements to have this work performed. HLA has presented costs to dispose the soil <br /> stockpiles and backfill the excavation in a letter dated July 25, 1991. <br /> T19461-H 19 of 20 <br />