Fourth Quarter 2004 <br /> Thrifty#172 <br /> January 19, 2004 <br /> Page 3 <br /> ethanol must continue to be analyzed for since it is a fuel additive at the site The SJCEHD <br /> further required that ethanol must be analyzed by EPA Method 8015 <br /> Remediation Status <br /> Vapor Extraction System <br /> On April 26, 2001, a new Baker Furnace Thermal Oxidizer Unit was placed into operation with <br /> the hour meter reading at zero Presently, the remediation system is connected to soil vapor <br /> extraction wells VW-1, VW-2 (A,B), VW-3, VW-4 (A,B,C), VW-5 (A,B,C), and VW-6 (A,B,C) <br /> as shown on Figure 6 <br /> During the fourth quarter of 2004, the soil vapor extraction unit (VEU) was down due to a <br /> problem with the extraction blower motor Thrifty sent the motor out for repair or replacement <br /> and recently was informed that the blower needed to be replaced Thrifty anticipates having the <br /> blower replaced and the VEU restarted by the end of January 2005 As of December 28, 2004, a <br /> • total of 92,537 pounds of hydrocarbons have been removed by the VEU (Table 3) Field Status <br /> Reports are included in Appendix C <br /> A historical summary of hydrocarbons removed by vapor extraction is presented in Table 3, vapor <br /> sample analytical results for the individual wells sampling are presented in Table 5 <br /> Groundwater Treatment System <br /> The groundwater treatment system was started in conjunction with the vapor treatment system on <br /> April 26, 2001, and the flow meter started at zero Presently, the remediation system is <br /> connected to groundwater well MW-11 A down-well pneumatic pump draws water into a 150- <br /> gallon polyvinyl tank, which then transfers the water through two (2) one thousand-pound <br /> granular activated carbon canisters in series <br /> During the reporting period, the system was shut down from October 1, 2004 and restarted <br /> October 5, 2004 for replacement of a sensor The system was shut down for carbon change out <br /> on the following dates October 13, 2004through Octoberl9, 2004, November 9, 2004 through <br /> November 18, 2004, and December 14 through December 21, 2004 A total of 34,422 gallons of <br /> water were treated and discharged during the reporting period, and 364,164 gallons had been <br /> treated and discharged since the commencement of groundwater treatment Historical <br /> groundwater system operations are reported in Table 4a and 4b, and the quarterly analytical <br /> results are presented in Appendix D <br />